نتایج جستجو برای: orotracheal intubation

تعداد نتایج: 15940  

2017
Jiyoung Lee Jong Yeop Kim Se Yoon Kang Hyun Jeong Kwak Dongchul Lee Sook Young Lee

BACKGROUND The McGrath videolaryngoscope (VL) provides excellent laryngoscopic views, but directing an endotracheal tube can be difficult, and thus the routine use of a stylet is recommended. The goal of this study is to determine the appropriate angle (60° vs 90°) of the stylet when using the McGrath VL by comparing the time to intubation (TTI). METHODS One hundred and forty patients aged 19...

Journal: :iranian journal of neonatology 0
seyedeh fatemeh khatami department of pediatric, devision of neonatology, tehran university of medical sciences, iran pouya parvaresh department of internal medicine, faculty of medical sciences szeged, medical university szeged, hungary shahin behjati department of pediatric, devision of neonatology, tehran university of medical sciences, iran

objective the purpose of this study was to assess the frequency of complications of endotracheal intubation (eti) in neonates. methods the newborns that were admitted and needed urgent or semi-urgent intubation were enrolled in this study over a 1 year period. route for intubation in all cases were orotracheal. cases were not routinely sedated or paralyzed. the patients were clinically and radi...

Journal: :Veterinary Record Case Reports 2022

A 9-year-old, male, 0.69 kg, corn snake was referred for enucleation of its right eye. Pre-anaesthetic medication consisted butorphanol (1 mg/kg) and alfaxalone (10 intramuscularly. Orotracheal intubation then performed. General anaesthesia maintained with sevoflurane in 100% oxygen. During the general anaesthesia, manually ventilated. At end surgery, orbit packed a haemostatic sponge soaked 0....

Journal: :Canadian journal of anaesthesia = Journal canadien d'anesthesie 2004
Mehmet Emin Orhan Ferruh Bilgin Mustafa Erdal Guzeldemir

To the Editor: We report a technique of orotracheal intubation using the combination of a flexible fibreoptic bronchoscope (FOB) and a stylet in a patient whose operation was postponed initially because of failed intubation. A 44-yr-old male was scheduled for total resection of the thyroid gland. After induction of anesthesia, a laryngeal view was not obtained by direct laryngoscopy. An experie...

Journal: :Canadian Anaesthetists' Society journal 1986
A D Sutherland J P Sale

Three cases of trismus caused by oropharyngeal sepsis are described where fibreoptic-assisted awake intubation using an oral airway intubator and nebulised lidocaine was safely and successfully achieved.

Journal: :Sao Paulo medical journal = Revista paulista de medicina 1998
L C Manganello-Souza N Tenorio-Cabezas L Piccinini Filho

OBJECTIVE To demonstrate an alternative method for intubating patients with fractures of maxilla and nose, prior to surgery. DESIGN Cases Report. PARTICIPANTS We studied 10 patients with facial fractures that affected maxilla and nose. INTERVENTION The patients were submitted to surgery under general anesthesia and submental oro-tracheal intubation. RESULTS This type of intubation allow...

2013
Sang-Kyi Lee A Ram Doo

Corresponding author: Sang-Kyi Lee, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Chonbuk National University Medical School & Chonbuk National University Hospital, 20, Gunji-ro, Deokjin-gu, Jeonju 561-710, Korea. Tel: 82-63-250-1250, Fax: 82-63-250-1240, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Co...

Journal: :Anaesthesia 2006
K B Greenland I D Ha M G Irwin

Sixty patients with no clinical indicators of a difficult airway were selected to undergo a fibreoptic assessment after induction of general anaesthesia using both the Berman Intubating Airway and the Williams Airway Intubator. The bronchoscopic view and ease of railroading a tracheal tube during fibreoptic orotracheal intubation were studied. The bronchoscopic views obtained by the Berman Airw...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید