نتایج جستجو برای: operative gamma camera

تعداد نتایج: 269893  

2012
David J. Hall Andrew Holland Matthew Soman

When considering the ‘standard’ gamma-camera, one might picture an array of photo-multiplier tubes or a similar array of small-area detectors. This array of imaging detectors would be attached to a corresponding array of scintillator modules (or a solid layer of scintillator) in order to give a high detection efficiency in the energy region of interest, usually 8-140 keV. Over recent years, dev...

Journal: :iranian journal of parasitology 0
tolga dinc dept. of general surgery, ankara numune training and research hospital, ankara, turkey selami ilgaz kayilioglu dept. of general surgery, ankara numune training and research hospital, ankara, turkey okan murat akturk dept. of general surgery, ankara numune training and research hospital, ankara, turkey faruk coskun dept. of general surgery, ankara numune training and research hospital, ankara, turkey

background: vast majority of complaints and physical examination findings of hydatid disease are common in emergency room patients. different emergency presentations of hydatid cyst disease and their treatment are evaluated. we studied preoperative laboratory findings of these patients to identify any parameters to predict hydatid cyst-biliary system communication. methods: we reviewed the file...

2005
G. Hermann S. Carrigan B. Glück D. Hauser

The Smart Pixel Camera is a new camera for imaging atmospheric Cherenkov telescopes , suited for a next generation of large multi-telescope ground based gamma-ray observatories. The design of the camera foresees all electronics needed to process the images to be located inside the camera body at the focal plane. The camera has a modular design and is scalable in the number of pixels. The camera...

Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...

2012
Marion Grapperon Mathis Charles Ley Mieth Berger Kerstin Hansson

BACKGROUND The current lack of a standardized protocol for positioning of the gamma camera relative to the horse limb in a lateral stifle scintigram, and thus the reliance on subjective positioning, may be a cause of diagnostic error and inter-operator variability due to variations of the view angle. The aims of this study were to develop a reliable method to obtain a lateral scintigram of the ...

2017
E. Goñi Gironés F. Vicente García P. Serra Arbeloa C. Estébanez Estébanez A. Calvo Benito I. Rodrigo Rincón A. Camarero Salazar M. E. Martínez Lozano

Aim: To define the sentinel node identification rate in breast cancer, the chronological evolution of this parameter and the influence of the introduction of a portable gamma camera. Material and methods: A retrospective study was conducted using a prospective database of 754 patients who had undergone a sentinel lymph node biopsy between January 2003 and December 2011. The technique was mixed ...

Journal: :Revista espanola de medicina nuclear e imagen molecular 2014
M Borbón-Arce O R Brouwer N S van den Berg H Mathéron W M C Klop A J M Balm F W B van Leeuwen R A Valdés-Olmos

PURPOSE Recent innovations such as preoperative SPECT/CT, intraoperative imaging using portable devices and a hybrid tracer were evaluated in a multimodality approach for sentinel node (SN) mapping and biopsy in head and neck malignancies. MATERIAL AND METHODS The evaluation included 25 consecutive patients with head and neck malignancies (16 melanomas and 9 oral cavity squamous cell carcinom...

Journal: :Singapore medical journal 2013
Yue-Hua Yang Yu-Ren Wang Sheng-Dan Jiang Lei-Sheng Jiang

INTRODUCTION Proximal femoral nail antirotation (PFNA) and third-generation Gamma nail (Gamma 3) are widely used in the treatment of intertrochanteric fractures. However, it remains unclear which device achieves better clinical and radiographic outcomes when treating intertrochanteric fractures. METHODS This study comprised 239 patients with intertrochanteric fractures treated with either PFN...

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید