In this study, fourteen sustainable concrete mixes containing metakaolin (MK) as supplementary cement material (SCM) and magnetized water (MW) mixing were designed, prepared, tested, analyzed, compared. The MK was used a partial replacement of weight by 5%, 10%, 20%, an additive to 20% weight. MW fully replace tap (TW) in prepared using two different magnetic fields 1.4 tesla (T) 1.6 T. This ex...