نتایج جستجو برای: isocratic separation
تعداد نتایج: 123941 فیلتر نتایج به سال:
A sensitive, isocratic reversed-phase high performance liquid chromatographic method involving fluorescence detection was developed for the determination of donepezil hydrochloride in tablets and in human plasma. Pindolol was used as an internal standard. Good chromatographic separation was achieved by using an analytical column C18. The system operated at room temperature using a mobile phase ...
A simple, rapid isocratic liquid chromatographic procedure with ultraviolet and fluorimetric detection is described for the separation and quantification of L-tryptophan (Trp) and six of its kynurenine metabolites (kynurenine, 3-hydroxykynurenine, and 3-hydroxyanthranilic, kynurenic, xanthurenic and anthranilic acids). Using the Perkin Elmer LC 200 system, a reverse phase Synergi 4 μ fusion-RP8...
The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of desvenlafaxine in bulk sample and pharmaceutical dosage form in the presence of degradation products. Forced degradation studies were performed on bulk sample of desvenlafaxine as per ICH prescribed stress conditions using aci...
Thiamine and its mono- and pyrophosphate esters were determined in beer and the raw materials used for its manufacture (brewer's yeast, malt, raw grain, and hops) after separation using reversed-phase liquid chromatography. The method used fluorescence detection and a new amide-based stationary phase, which avoids the need to form ion pairs, leading to narrower peaks and a simpler mobile phase....
A fast and robust RP-HPLC isocratic method was developed for determination of piroxicam in bulk materials and pharmaceutical formulations. Optimum separation of piroxicam and stress induced degradation a product was achieved using a SB-C18 Eclipse column (150x4.6; 5μm). The mobile phase was a mixture of water: acetonitrile (50:50) with a flow rate of 0.5mL/min. The UV detection was performed at...
A stability-indicating assay by reversed-phase high performance liquid chromatography method was developed and validated for the determination of sulthiame (STM). The chromatographic separation was achieved on a reversed-phase NovaPack C18 column and an isocratic mobile phase consisting of deionized water:methanol (70:30, v/v). The flow rate was 1.0 mL/min (ultraviolet detection at 210 nm). The...
The most suitable bio-analytical method based on liquid-liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm×50 mm, 3.5 μm) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved...
A HPLC method has been described for simultaneous determination of Losartan potassium and Metolazone in formulation. This method is based on a HPLC separation of the two drugs on the Thermo Hypersil BDS-C(18) (250 mm × 4.6 mm, 5.0 μm) with isocratic conditions and a simple mobile phase containing acetonitrile:water (60:40) at a flow rate of 0.8 mL/min using UV detection at 237 nm. This method h...
A rapid and sensitive HPLC method has been developed for the quantification of mirtazapine (MRZ), a noradrenergic and specific serotonergic inhibitor antidepressant (NaSSA) and its two major metabolites N-desmethyl mirtazapine (NDM) and 8-hydroxymirtazapine (8-OHM) in human plasma. The separation was achieved using Chromolith C18 column and a mobile phase of acetonitrile: phosphate buffer (pH =...
An isocratic liquid chromatographic method with UV detection at 220 nm is described for simultaneous determination of ceftriaxone sodium and sulbactam sodium in Sulbactomax. Chromatographic separation of two drugs was achieved on a Hypersil ODS C-18 column using a mobile phase consisting of a binary mixture of acetonitrile and tetrabutyl ammonium hydroxide adjusted to pH7.0 with orthophosphoric...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید