نتایج جستجو برای: gafchromic film film dosimetry

تعداد نتایج: 98485  

Journal: :Radiotherapy and Oncology 2019

Journal: :iranian journal of radiation research 0
a.a. mowlavi physics department, school of sciences, sabzevar tarbiat moallem university, sabzevar, iran f. cupardo servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy m. severgnini servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy

background: monte carlo and experimental relative dose determination in a water phantom, due to a high dose rate (hdr) 192ir source is presented for real energy spectrum and monochromatic at 356 kev. materials and methods: the dose distribution has been calculated around the 192ir located in the center of 30 cm ×30 cm ×30 cm water phantom using mcnp4c code by monte carlo method. relative dose v...

Journal: :Medical physics 2009
Harshad Sakhalkar David Sterling John Adamovics Geoffrey Ibbott Mark Oldham

This study presents the application of the Presage/optical-CT 3D dosimetry system for relative dosimetry in the Radiologic Physics Center (RPC) Head and Neck (H&N) IMRT phantom. Performance of the system was evaluated by comparison with the "gold-standard" RPC credentialing test. A modified Presage cylindrical insert was created that extended the capability of the RPC H&N phantom to 3D dosimetr...

2008
Parminder Basran Collins Yeboah

A methodology for the dosimetric verification of micro-multileaf collimator MMLC) based intensity modulated radiation therapy (IMRT) plans intended for stereotactic applications is described. The procedure is similar to that of conventional IMRT patient-specific quality assurance with some notable exceptions. Relative dosimetry measurements are performed with radiographic film, a commercial fil...

2012
Hani Alnawaf Peter K.N. Yu Martin Butson

Epson Desktop scanners have been quoted as devices which match the characteristics required for the evaluation of radiation dose exposure by radiochromic films. Specifically, models such as the 10000XL have been used successfully for image analysis and are recommended by ISP for dosimetry purposes. This note investigates and compares the scanner characteristics of three Epson desktop scanner mo...

2006
E. O ' Shea P. McCavana

Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface." Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energ...

2012
Luigi Tommasino

The present paper deals with the solid state etch-track detectors and their applications to the detection/dosimetry of neutrons, radon, and radon-decay products. Most of the scientists, actively engaged in the late 60’s and in the 70’s for monitoring the occupational neutron-exposure by etch-track detectors, became also involved in the development of personal monitors for the exposure to radon-...

Journal: :Journal of Applied Clinical Medical Physics 2007

Journal: :Journal of Applied Clinical Medical Physics 2012

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید