نتایج جستجو برای: fricke gel dosimeter

تعداد نتایج: 107206  

Journal: :Physics in medicine and biology 2001
P M Fong D C Keil M D Does J C Gore

Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere a...

2013
T Juang J Newton S Das J Adamovics M Oldham

Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter...

2015
Masayori Ishikawa Naomi Nagase Taeko Matsuura Junichi Hiratsuka Ryusuke Suzuki Naoki Miyamoto Kenneth Lee Sutherland Katsuhisa Fujita Hiroki Shirato

The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filte...

Journal: :Revista investigaciones y aplicaciones nucleares 2022

La dosimetría Fricke es una técnica con múltiples aplicaciones, desde la industria alimentaria hasta medicina. En las actividades cotidianas de planta irradiación gamma del Servicio Geológico Colombiano (SGC) se usan diferentes sistemas dosimétricos para el estudio dosis absorbidas en los materiales, entre ellos sistema dosimétrico Fricke. este trabajo realizó comparación absorbida determinada ...

2008
Yves De Deene

The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...

Journal: :The Laryngoscope 2015
Stephanie Misono Kathryn Banks Philippe Gaillard George S Goding Bevan Yueh

OBJECTIVES/HYPOTHESIS Voice rest is frequently recommended following surgical disruption of vocal fold epithelium, but patients report variable adherence to voice rest recommendations. The objective of this study was to assess the clinical utility of an ambulatory vocal dosimeter for measuring adherence to voice rest recommendations. STUDY DESIGN Outcomes research. METHODS Part 1: To determ...

2017
Kalin I Penev Meng Wang Kibret Mequanint

Tetrazolium salts (TS) have been previously used for radiochromic dosimetry in solutions, films and three dimensional (3D) gelatine-based gels. However, widespread application for 3D dosimetry has not been achieved due to the required high concentrations and associated high costs of the TS dimer used in prior research. Through careful selection of TS monomer, sensitivity-enhancing additives and...

2010
A E Papadakis T G Maris G Zacharakis J Ripoll

We present initial results on the comparison of the dose readout from a three dimensional polymer gel dosimeter using two different optical-CT systems; i) a common wide field and a wide area detector optical-CT system and ii) a new ‘laser-line’ and wide area detector based optical-CT system. The findings presented herein highlight the advantage of the laser based over the wide field optical-CT ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید