نتایج جستجو برای: fractionated plasma separation and adsorption

تعداد نتایج: 16912222  

ژورنال: Medical Laboratory Journal 2016
Ariaie , Mohammad, Joshaghani, Hamidreza, Aliarab, azadeh, Mirfazeli , Arezoo , Mohammad Abadi , Fahime , Nejabat, Mojgan , taherizadeh, Mahsa , Zaeri , Hossein ,

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

Journal: :Food technology and biotechnology 2016
Josip Ćurko Marin Matošić Vlado Crnek Višnja Stulić Ivan Mijatović

The aim of this study is to determine the adsorption performance of three types of adsorbents for removal of As(V) from water: Bayoxide® E33 (granular iron(III) oxide), Titansorb® (granular titanium oxide) and a suspension of precipitated iron(III) hydroxide. Results of As(V) adsorption stoichiometry of two commercial adsorbents and precipitated iron(III) hydroxide in tap and demineralized wate...

Journal: :International Journal of Molecular Sciences 2009
Nor Dyana Zakaria Nor Azah Yusof Jelas Haron Abdul Halim Abdullah

Molecular imprinted polymers (MIP) are considered one of the most promising selective and novel separation methods for removal phenolic compound in wastewater treatment. MIP are crosslinked polymeric materials that exhibit high binding capacity and selectivity towards a target molecule (template), purposely present during the synthesis process. In this work MIP were prepared in a bulk polymeriz...

Journal: :Journal of biomedical materials research 1990
A Poot T Beugeling W G van Aken A Bantjes

In view of reports on the involvement of high-molecular-weight (HMW) kininogen and high-density lipoprotein (HDL) in the Vroman effect, we studied the adsorption of fibrinogen, HMW kininogen, HDL and several other proteins from pooled human plasma and congenitally HMW kininogen-deficient plasma onto glass and low-density polyethylene, both as a function of the plasma concentration and the conta...

Journal: :Physical chemistry chemical physics : PCCP 2014
I Matito-Martos A Martin-Calvo J J Gutiérrez-Sevillano M Haranczyk M Doblare J B Parra C O Ania S Calero

We used a combination of experiments and molecular simulations to investigate at the molecular level the effects of zeolite structure on the adsorption and diffusion of sulfur dioxide, carbon dioxide and carbon monoxide as well as separation processes of their mixtures. Our study involved different zeolite topologies and revealed numerous structure-property trends depending on the temperature a...

H. Ghafourian H. Zargarlellahi,

Toxicity has occurred in workers exposed to nickel dust or nickel carbonyl formed in refining. Increased risk of nasal and lung cancers was linked to occupational nickel exposure before current workplace safety standards were set. Activated carbon with nano holes used for removing contaminants in environment. The purpose of this work is preparation a new nano-absorber, GZ-BAKI-TAC-Ni-88, for th...

Journal: Nanochemistry Research 2018

An efficient and simple magnetic solid phase extraction based on the use of CoFe3O4 nanoparticles grafted multi-walled carbon nanotubes (MWCNTs) as adsorbent coupled with surfactant enhanced spectrofluorimetric detection...

Journal: :iranian journal of biotechnology 2014
kamran mousavi hosseini mojgan pourmokhtar mehryar habibi roudkenar majid shahabi

background: there are varieties of purification techniques for separation of human plasma proteins such as salting out, ion exchange chromatography, and ethanol fractionation. there are limitations for each method, for example in salting out method, the salt has to be removed in an additional step. ion exchange chromatography is difficult for scaling up, and plasma fractionation is a time consu...

2011
Renato Millioni Serena Tolin Lucia Puricelli Stefano Sbrignadello Gian Paolo Fadini Paolo Tessari Giorgio Arrigoni

BACKGROUND To date, the complexity of the plasma proteome exceeds the analytical capacity of conventional approaches to isolate lower abundance proteins that may prove to be informative biomarkers. Only complex multistep separation strategies have been able to detect a substantial number of low abundance proteins (<100 ng/ml). The first step of these protocols is generally the depletion of high...

In this study pre-combustion capture of carbon dioxide from hydrogen was performed using a 5A zeolite adsorber. A one column thermal pressure swing adsorption (TPSA) process was studied in the bulk separation of a CO2/H2 mixture (50:50 vol%). The adsorption dynamics of the zeolite bed were investigated by breakthrough experiments to select the suitable range for operational factors in the desig...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید