The capability to perform multicolor, wide field-of-view (FOV) fluorescence microscopy imaging is important in screening and pathology applications. We developed a microscopic slide-imaging system that can achieve multicolor, wide FOV, fluorescence imaging based on the Talbot effect. In this system, a light-spot grid generated by the Talbot effect illuminates the sample. By tilting the excitati...
An integrated gamma ray spectrometer, incorporating a germanium detector with integral mechanical cooling, digital signal processing electronics, MCA, and communications has been developed. It is intended as a modular subsystem for wide application, including use in stationary or mobile systems for the detection of radioactive materials. The requirements for this application are good low and me...
To address the need for high resolution detection systems to be used in portal monitors and mobile search systems, an integrated gamma ray spectrometer, incorporating a germanium detector with integral mechanical cooling, digital signal processing electronics, MCA, and communications has been developed. This modular subsystem can be used in a wide variety of applications, including use in stati...
We have recently introduced the concept of C-space entropy as a measure of knowledge of C-space for sensor-based path planning and exploration for general robot-sensor systems [1, 2, 3, 5]. The robot plans the next sensing action to maximally reduce the expected C-space entropy, also called the maximal expected entropy reduction, or MER criterion. The expected C-space entropy computation, howev...
Positron emission tomography (PET) scanners designed to image animals the size of rats and mice should possess simultaneously high and uniform spatial resolution and high sensitivity. ATLAS (Advanced Technology Laboratory Animal Scanner), a 6.0 cm diameter effective transverse field-of-view (FOV), 2 cm axial FOV ring-type research scanner seeks these goals by surrounding the animal with eightee...
INTRODUCTION Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans-catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X-ray beam from the C-arm altered the appearance of the TAVR device. METHODS Under bench-top testing, a 23, 26 and 29 mm Edwards Sapien XT val...
Time-lapse or longitudinal fluorescence microscopy is broadly used in cell biology. However, current available time-lapse fluorescence microscopy systems are bulky and costly. The limited field-of-view (FOV) associated with the microscope objective necessitates mechanical scanning if a larger FOV is required. Here we demonstrate a wide FOV time-lapse fluorescence self-imaging Petri dish system,...
BACKGROUND The teeth with undiagnosed vertical root fractures (VRFs) are likely to receive endodontic treatment or retreatment, leading to frustration and inappropriate endodontic therapies. Moreover, many cases of VRFs cannot be diagnosed definitively until the extraction of tooth. OBJECTIVES This study aimed to assess the use of different voxel resolutions of two different cone beam compute...