نتایج جستجو برای: film dosimeter
تعداد نتایج: 92845 فیلتر نتایج به سال:
Following a previous feasibility study, a photon dosimeter have been constructed by attaching a small piece of BGO scintillator to a low attenuation plastic optical fiber for which the light output is measured with a current-type PMT. The dosimeter model is tested in a Co irradiation chamber in the dose rate range varying from about 50 to 1200 Gy/h. The dose rates are measured at a number of pr...
PURPOSE To determine whole body and hand radiation exposure to the hand surgeon wearing a lead apron during routine intraoperative use of the mini C-arm fluoroscope. METHODS Four surgeons (3 hand attending surgeons and 1 hand fellow) monitored their radiation exposure for a total of 200 consecutive cases (50 cases per surgeon) requiring mini C-arm fluoroscopy. Each surgeon measured radiation ...
STUDY DESIGN Prospective study. PURPOSE During fluoroscopically guided spinal procedure, the hands of spinal surgeons are placed close to the field of radiation and may be exposed to ionizing radiation. This study directly measured the radiation exposure to the hand of a spinal interventionalist during fluoroscopically guided procedures. OVERVIEW OF LITERATURE Fluoroscopically guided spinal...
The Radiation Monitor (RADOM) payload is a miniature dosimeter-spectrometer onboard Chandrayaan-1 mission for monitoring the local radiation environment in nearEarth space and in lunar space. RADOM measured the total absorbed dose and spectrum of the deposited energy from high energy particles in near-Earth space, en-route and in lunar orbit. RADOM was the first experiment to be switched on soo...
background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...
in radiation cancer treatments, the most of the side effects could be minimized using a proper dosimeter. gel dosimeter is the only three‑dimensional dosimeter and magnetic resonance imaging (mri) is the gold standard method for gel dosimeter readout. because of hard accessibility and high cost of sample reading by mri systems, some other alternative methods were developed. the optical computed...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید