نتایج جستجو برای: epid

تعداد نتایج: 673  

Journal: :Medical physics 2002
Sandra C Vieira Maarten L P Dirkx Kasper L Pasma Ben J M Heijmen

A prerequisite for accurate dose delivery of IMRT profiles produced with dynamic multileaf collimation (DMLC) is highly accurate leaf positioning. In our institution, leaf verification for DMLC was initially done with film and ionization chamber. To overcome the limitations of these methods, a fast, accurate and two-dimensional method for daily leaf verification, using our CCD-camera based elec...

2015
Jinhan Zhu Lixin Chen Along Chen Guangwen Luo Xiaowu Deng Xiaowei Liu

PURPOSE To use a graphic processing unit (GPU) calculation engine to implement a fast 3D pre-treatment dosimetric verification procedure based on an electronic portal imaging device (EPID). METHODS The GPU algorithm includes the deconvolution and convolution method for the fluence-map calculations, the collapsed-cone convolution/superposition (CCCS) algorithm for the 3D dose calculations and ...

2015
Iori Sumida Hajime Yamaguchi Hisao Kizaki Keiko Aboshi Mari Tsujii Yuji Yamada Masashi Yagi Kazuhiko Ogawa

Pretreatment dose verification with beam-by-beam analysis for intensity-modulated radiation therapy (IMRT) is commonly performed with a gantry angle of 0° using a 2D diode detector array. Any changes in multileaf collimator (MLC) position between the actual treatment gantry angle and 0° may result in deviations from the planned dose. We evaluated the effects of MLC positioning errors between th...

2006
Miao Zhang Vitali Moiseenko Mitchell Liu

Using internal fiducial markers and electronic portal imaging (EPID) to realign patients has been shown to significantly reduce positioning uncertainties in prostate radiation treatment. This creates the possibility of decreasing the planning target volume (PTV) margin added on the clinical target volume (CTV), which in turn may allow for dose escalation. We compared the outcome of two plans: 7...

Journal: :Medical physics 2009
Arun Gopal Sanjiv S Samant

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal...

Journal: :Journal of Applied Clinical Medical Physics 2006

Journal: :Neuro-oncology 2022

Abstract BACKGROUND No consensus germline testing guidelines currently exist for glioma patients. Hence such is not routinely performed. The prevalence and type of pathogenic variants in these brain tumors remains unknown. DESIGN/ METHODS A retrospective review patients treated at Baylor College Medicine with paired tumor/normal sequencing using the Tempus xT matched approach from August 2018- ...

2015
Charbel Merheb Clément Chevillard Wassim Ksouri Maher Fawzi Marc Bollet Alain Toledano

Several algorithms exist to perform quality assurance for volumetric-modulated arc therapy (VMAT) treatments based on electronic portal imaging devices (EPID). These algorithms are used to compare doses (convert into water, GLAaS) and fluences (in amorphous silicon (aSi), Varian portal dosimetry). The aim of this study is to compare the two methods using clinical data. In this study, Varian por...