نتایج جستجو برای: energy resolution

تعداد نتایج: 928621  

2004
B. T. SUTCLIFFE J. TENNYSON

The state-of-the-art in non-empirical calculations of potential energy surfaces for small molecules is discussed, as is the present position with respect to the analytic fitting of such surfaces. The results of some nonempirical vibration-rotation calculations performed on such analytic surfaces are presented and compared with experimental results. An attempt is made to assess the extent to whi...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
J M dos Santos C M Monteiro

The response of a high-purity germanium detector to X-rays in the 8-15-keV energy region has been investigated. The w-value and energy resolution dependencies on the X-ray energy have been studied. No abrupt variation of w is observed at the germanium K absorption-edge (11.104-keV). The detector energy resolution follows a characteristic linear dependence on Ex(-1/2) over the whole energy range...

1999
W. Hofmann H. Krawczynski

We present analysis techniques to improve the energy resolution of stereoscopic systems of imaging atmospheric Cherenkov telescopes, using the HEGRA telescope system as an example. The techniques include (i) the determination of the height of the shower maximum, which is then taken into account in the energy determination, and (ii) the determination of the location of the shower core with the a...

2016
O Belgacem E Pittenauer M E Openshaw P J Hart A Bowdler G Allmaier

RATIONALE For the last two decades, curved field reflectron technology has been used in matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometers, assisting in the generation of post-source-decay (PSD) or collision-induced dissociation (CID) without decelerating precursor ions, producing true high-energy CID spectra. The result was the generation of product ion m...

Journal: :journal of medical signals and sensors 0
mohsen hajizadeh-safar m ghorbani s khoshkharam z ashrafi

gamma camera is an important apparatus in nuclear medicine imaging. its detection part is consists of a scintillation detector with aheavy collimator. substitution of semiconductor detectors instead of scintillator in these cameras has been effectively studied. in this study, it is aimed to introduce a new design of p-n semiconductor detector array for nuclear medicine imaging. a p-n semiconduc...

2014
Paul Cueva David A. Muller

Despite being diffraction limited to thousands of Ångstroms, infrared and optical spectroscopies remain effective characterization techniques. While it is possible to perform subatomic resolution electron energy loss spectroscopy (EELS) at unprecedented energy resolution, with ever improving aberration correctors and monochromators, it is argued that low loss features can be severely delocalize...

2009
S. Surti P. S. Raby

The main thrust for this work is the investigation and design of a positron emission tomography (PET) scanner based on new Lanthanum Halide scintillators. In three–dimensional (3-D) PET the major limitations are scanner dead-time and ability to reject randoms and scatter. Therefore, to reach the full potential of 3-D PET requires a scintillator with good timing resolution and good energy resolu...

Journal: :Physical review letters 2011
Nima Tabatabaei Andreas Mandelis

Energy transport in diffusion-wave fields is gradient-driven and therefore diffuse, yielding depth-integrated responses with poor axial resolution. Using matched-filter principles, we propose a methodology enabling these parabolic diffusion-wave energy fields to exhibit energy localization akin to propagating hyperbolic wave fields. This not only improves axial resolution but also allows for de...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2011

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید