نتایج جستجو برای: dose limits

تعداد نتایج: 428973  

H. Afarideh, M.R. Kardan, N. Navab Moghadam, S.M. Hosseini Pooya,

Background: Different kinds and models of personal dosimeters are used in individual monitoring by workers.  Performance testing as part of approval procedures is carried out to demonstrate that the essential performance specifications are routinely maintained. There are four service providers in Iran which use different luminescence techniques (i. e. TLD and RPL) with various kinds of dos...

Introduction Recent studies of public underground parking lots showed the influence of radon concentration and the probable discomfort caused by parking cars. Materials and Methods Radon concentration was measured in semi-closed public parking lots in the six governorates of Kuwait, using Durridge RAD7radon detector (USA). Results The peak radon concentration in the parking lots of Kuwait gover...

S. Mullainathan, S. Murugesan, V. Meenakshisundaram, V. Ramasamy,

Background: Natural radiation is constantly present in the environment and is emitted from a variety of natural and artificial sources. It affects human body and environment. Materials and Methods: The activity concentrations of 238U, 232Th and 40K have been determined by Gamma ray spectrometer with an HPGe detector in sediments of Cauvery River, Tamilnadu, India. Results: The absorbe...

Journal: :Medical Image Analysis 2021

Radiation exposure in positron emission tomography (PET) imaging limits its usage the studies of radiation-sensitive populations, e.g., pregnant women, children, and adults that require longitudinal imaging. Reducing PET radiotracer dose or acquisition time reduces photon counts, which can deteriorate image quality. Recent deep-neural-network (DNN) based methods for image-to-image translation e...

Journal: :Physics in medicine and biology 2010
I Martínez-Rovira J Sempau J M Fernández-Varea A Bravin Y Prezado

The purpose of this work is to define safe irradiation protocols in microbeam radiation therapy. The intense synchrotron-generated x-ray beam used for the treatment is collimated and delivered in an array of 50 microm-sized rectangular fields with a centre-to-centre distance between microplanes of 400 microm. The absorbed doses received by the tumour and the healthy tissues in a human head phan...

2015
Yuji Kumagai Tomoko Hasunuma Soichi Sakai Hidekazu Ochiai Yoshishige Samukawa Renate B Schnabel

Luseogliflozin is a selective sodium glucose co-transporter 2 (SGLT2) inhibitor. To evaluate the cardiac safety of luseogliflozin, a thorough QT/QTc study was conducted in healthy Japanese subjects. The effects of moxifloxacin on QT prolongation in Japanese subjects were also evaluated. In this double-blind, placebo- and open-label positive-controlled, 4-way crossover study, 28 male and 28 fema...

2016
Jung‐in Kim Jin‐Beom Chung Ju‐Young Song Sung Kyu Kim Yunseok Choi Chang Heon Choi Won Hoon Choi Byungchul Cho Jin Sung Kim Sung Jin Kim Sung‐Joon Ye

This study aims to investigate tolerance levels for patient-specific IMRT dose QA (DQA) using the confidence limits (CL) determined by a multi-institutional study. Eleven institutions participated in the multi-institutional study in Korea. A total of 155 DQA measurements, consisting of point-dose differences (high- and low-dose regions) and gamma passing rates (composite and per-field) for IMRT...

Journal: :iranian journal of public health 0
v changizi ma oghabian

ct.scan examinations cause high patient absorbed dose from x-ray ionizing radiation. therefore it is necessary to obtain superficial dose profile in z-line. in this research 11 thermoluminecent dosimeter (tld), after calibration were located on z line perpendicular to slice thickness. ct.scan machines did x-ray exposures. the resultant dose profiles showed gussian shape apperience, which has se...

Journal: :iranian journal of radiation research 0
m. hajizadeh saffar medical physic research centre, bu-ali research institute, mashhad medical school, mashhad, iran s. nekoee medical physic research centre, bu-ali research institute, mashhad medical school, mashhad, iran e. hajizadeh saffar medical physic research centre, bu-ali research institute, mashhad medical school, mashhad, iran

background: a study has been conducted to assess two useful radiation protection indices, the annual per-capita effective dose equivalent (aed) and the genetically significant dose (gsd), from conventional diagnostic radiography in 10 counties with more than 1,886,000 inhabitants in khorasan province in iran. materials and methods: the health centre authorities of khorasan province were asked t...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri department of medical physics, shahid sadoghi university of medical sciences, yazd, iran m.h. dashti department of physiology, shahid sadoghi university of medical sciences, yazd, iran m.h. zare department of medical physics, shahid sadoghi university of medical sciences, yazd, iran

background: radiation dose knowledge through xray examinations and their distribution in iran provides useful guidance on patient dose reduction. the results of the entrance skin dose (esds) of five common radiographies in all radiology centers in yazd province were reported in our previous study (2003). in the present study we have evaluated the collective effective dose of conventional x-ray ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید