نتایج جستجو برای: diffractometer

تعداد نتایج: 1342  

2011
Ron Smith

In order to fit the peaks observed in a time-of-flight diffraction experiment two sets of information are required. The first set, the diffractometer constants, is used to calculate the time-of-flight positions of the Bragg reflections (whose d-spacings can be determined from the unit cell parameters and space group information). The second set, the profile parameters, are used to calculate the...

2013
S. Disch

Figure S1: X-ray powder diffraction pattern of the iron oxide nanospheres sample. X-ray Powder diffraction (XRPD) was measured on a conventional in-house powder diffractometer using Cu Kα radiation. Rietveld refinement yields cubic lattice parameters of 8.362(2) Å for the nanospheres and 8.348(1) Å for the nanocubes, which are both close to the cubic spinel lattice parameter of maghemite. The r...

2012
Gabriela Weber

The stoicheiometrically 1:1 adduct of 1,4,7,10,13,16-hexaoxa-cyclooctadecane with m-nitroaniline, C18H30N2O8, Mr = 402.45, crystallises from toluene in red-orange prisms, (probable) space group P i , a = 801.8(3), b = 920.4(3), c = 1403.3(4) pm, a = 80.40(4), ß = 79.79(4), y = 85.95(3)°, V = 1.07910 nm3, Z = 2, dcaic. = 1.238 Mgm~3. Structure refinement converged at R = 0.060 (Rw = 0.002) for 2...

2016
Takashi Ohhara Ryoji Kiyanagi Kenichi Oikawa Koji Kaneko Takuro Kawasaki Itaru Tamura Akiko Nakao Takayasu Hanashima Koji Munakata Taketo Moyoshi Tetsuya Kuroda Hiroyuki Kimura Terutoshi Sakakura Chang-Hee Lee Miwako Takahashi Ken-ichi Ohshima Tamiko Kiyotani Yukio Noda Masatoshi Arai

SENJU is a new single-crystal time-of-flight neutron diffractometer installed at BL18 at the Materials and Life Science Experimental Facility of the Japan Accelerator Research Complex (J-PARC). The diffractometer was designed for precise crystal and magnetic structure analyses under multiple extreme sample environments such as low temperature, high pressure and high magnetic field, and for diff...

2013
H Canova A Fontoura R T Neuenschwander B Diaz C B Rodella

XRD1 was the first X-ray diffraction beamline to be built at the LNLS and after approximately 12 years of operation it was substantially updated to improve beam stability, increase the reliability of the monochromator movement as well as provide an experimental hutch that would meet the demands of users. The improvements included the construction of an independent concrete slab below the mirror...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2014
V Tudisca F Bruni E Scoppola R Angelini B Ruzicka L Zulian A K Soper M A Ricci

The process of dynamical arrest, leading to formation of different arrested states such as glasses and gels, along with the closely related process of aging, is central for both basic research and technology. Here we report on a study of the time-dependent structural evolution of two aqueous Laponite clay suspensions at different weight concentrations. Neutron diffraction experiments have been ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید