نتایج جستجو برای: commissioning beam

تعداد نتایج: 116791  

2017
Jeffrey E. Snyder Ryan T. Flynn Daniel E. Hyer

The accurate delivery of respiratory-gated volumetric modulated arc therapy (VMAT) treatment plans presents a challenge since the gantry rotation and collimator leaves must be repeatedly stopped and set into motion during each breathing cycle. In this study, we present the commissioning process for an Anzai gating system (AZ-733VI) on an Elekta Versa HD linear accelerator and make recommendatio...

1999
L. Emery

The Advanced Photon Source (APS) is a 7-GeV, thirdgeneration synchrotron radiation source. To provide more stable beam for users, in September 1998 we began commissioning a new operating mode called “top-up.” In this mode, the beam current does not decay but is maintained at a high level using frequent injection, while photon shutters are open and photon beams are delivered to users. The hardwa...

2010
Sha Bai Jie Gao Philip Bambade Benoit Bolzon

The ATF2 project is the final focus system prototype for ILC and CLIC linear collider projects, with a purpose to reach a 37nm vertical beam size at the interaction point. During initial commissioning, we started with larger than nominal !-functions at the IP, to reduce the effects from higher-order optical aberrations and thereby simplify the optical corrections needed. We report on simulation...

2011
D Parno

A wide range of nucleon and nuclear structure experiments in Jefferson Lab’s Hall A require precise, continuous measurements of the polarization of the electron beam. In our Compton polarimeter, electrons are scattered off photons in a Fabry-Perot cavity; by measuring an asymmetry in the integrated signal of the scattered photons detected in a GSO crystal, we can make non-invasive, continuous m...

Journal: :Optics letters 2016
Li-Wei Wei Frédéric Cleva Catherine Nary Man

Stable low-noise high-power lasers are indispensable in advancing the strain sensitivity of interferometric gravitational wave detectors. Advanced LIGO and Advanced Virgo are currently under commissioning and require about 200 W of single-frequency laser power, while the future detector design may require up to the order of 500 W. In this Letter, we present the design and, to the best of our kn...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2017
Juan Diego Azcona Benigno Barbés Verónica Morán Javier Burguete

This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15 mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in sca...

2000
P. Forck F. Heymach T. Hoffmann A. Peters P. Strehl

For the characterization of the 10 mA ion beam delivered by the new High Current Linac at GSI, sophisticated , mainly non-intersepting diagnostic devices were developed. Besides the general setup of a versatile test bench, we discuss in particular bunch shape and emittance measurements. A direct time-of-flight technique with a diamond particle detector is used to observe the micro-bunch distrib...

2000
W. Kozanecki

The successful commissioning and operation of the PEP-II asymmetric ee collider motivated further studies to increase luminosity. In this paper, we discuss a modification of the PEP-II lattice to reduce the vertical beta function at the Interaction Point (IP) from the design value of β∗ y = 1.5cm to 1.0cm. This could potentially reduce the colliding beam size, increase the particle density at I...

2010
T. Miyajima Y. Honda M. Yamamoto T. Uchiyama K. Sato S. Nozawa M. Tobiyama T. Mitsuhashi T. Obina R. Takai T. Takahashi T. Ozaki A. Ueda S. Nagahashi M. Shimada K. Haga T. Honda K. Harada E. Nakamura S. Sakanaka

In order to develop the photo cathode gun for the Compact ERL (cERL), which is a test accelerator to establish accelerator technologies for GeV-class synchrotron light source based on ERL (Energy Recovery Linac), Gun Test Facility is constructing in KEK, AR south experimental hall. The Gun Test Facility consists of a 500 kV gun construction area, a laser system area and a gun test beamline with...

2002
M. Tischer P. Ilinski U. Hahn J. Pflüger H. Schulte-Schrepping

An X-ray diagnostic station will be installed for each of the XFEL undulator beamlines at TESLA. Primary purpose of the X-ray diagnostics is to provide an additional tool for alignment and commissioning of the numerous undulator cells along an XFEL beamline independently from electron beam based alignment procedures. Both methods will complement one another. The X-ray diagnostic station will be...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید