نتایج جستجو برای: axially moving beam
تعداد نتایج: 218900 فیلتر نتایج به سال:
This article demonstrates a new approach for nonlinear finite element analysis. The methodology is very suitable and gives very accurate results in linear as well as in nonlinear range of the material behavior. Proposed methodology can be regarded as stress based finite element analysis as it is required to define the stress distribution within the structural body with structural idealization a...
BACKGROUND Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams. METHODS A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam po...
Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existi...
In the present analysis, an infinite Euler– Bernoulli beam of constant cross-section resting on an elastic foundation is considered. The beam and foundation are assumed to be homogeneous and isotropic. The foundation is modeled using one parameter without damping. The beam is subjected to a constant point load moving with a constant speed along the beam. An effort has been made to find the solu...
Flutter and Divergence Instability of Axially-Moving Nanoplates Resting on a Viscoelastic Foundation
ABSTRACT The prototype superconducting cavity system for CESRPhase III was tested in CESR in August 1994. The performance of the system was very gratifying. The cavity operated gradients of 4.5-6 MV/m and accelerated beam currents up to 220 mA. This current is a factor of 3 above the world record 67 mA for SRF[1]. The high circulating beam current did not increase the heat load or present any d...
We present a new powerful liquid hydrogen target developed for the precise study of parity violating electron scattering on hydrogen and deuterium. This target has been designed to have minimal target density fluctuations under the heat load of a 20μA CW 854.3 MeV electron beam without rastering the electron beam. The target cell has a wide aperture for scattered electrons and is axially symmet...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید