نتایج جستجو برای: application radiotherapy dosimetry

تعداد نتایج: 830352  

Alireza Shirazi, Hamid Reza Sadoughi Hasan Nedaei Mahbod Esfahani Mahmood Allahverdi Ramin Jaberi

Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....

Journal: :Zeitschrift fur medizinische Physik 2011
Thomas Goetzfried Mark Rickhey Marius Treutwein Oliver Koelbl Ludwig Bogner

Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were r...

Journal: :Physics in medicine and biology 2014
A Subiel V Moskvin G H Welsh S Cipiccia D Reboredo P Evans M Partridge C DesRosiers M P Anania A Cianchi A Mostacci E Chiadroni D Di Giovenale F Villa R Pompili M Ferrario M Belleveglia G Di Pirro G Gatti C Vaccarezza B Seitz R C Isaac E Brunetti S M Wiggins B Ersfeld M R Islam M S Mendonca A Sorensen M Boyd D A Jaroszynski

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibrat...

Journal: :Medical physics 2011
James A Tanyi Kevin D Nitzling Camille J Lodwick Alan L Huston Brian L Justus

PURPOSE Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. METHODS The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and...

2015
Eduardo Rosenblatt Eduardo Zubizarreta Joanna Izewska Sergio Binia Fernando Garcia-Yip Pablo Jimenez

BACKGROUND In Latin America radiotherapy quality varies significantly among hospitals, where highly equipped academic centers coexist with others not meeting minimal requirements. In 2007, the International Atomic Energy Agency published guidelines for auditing radiotherapy centers, known as the "Quality Assurance Team for Radiation Oncology" (QUATRO) audits. The present report summarizes a pil...

2017
D. MIHAILESCU C. BORCIA

Dose distributions in different models of inhomogeneous phantoms irradiated with 3 19 MeV electron beams have been calculated using DOSXYZnrc/EGSnrc Monte Carlo code. The rectilinear 3D voxel phantoms, relevant for radiotherapy and clinical dosimetry, were built from ICRU soft tissue equivalent material in which was inserted a single layer of bone, lung, air or Titanium. Significant interface e...

Fariba Eyni Maryam Atarod, Mohammad Javad Tahmasebi Birgani Nahid Chegeni Seyed Mojtaba Hosseini

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

2013
Christiane Schuchardt Harshad Kulkarni Carolin Zachert Richard P Baum

Aim: Calculating the absorbed dose is important for the determination of risk and therapeutic benefit of internal radiation therapy. Optimal dose estimations require time-consuming and sophisticated methods, which are difficult due to practical reasons. To make dosimetry available for each of the patients, we developed a specific dosimetry procedure used in daily clinical routine. Materials and...

2017
Katarina Sjögreen Gleisner Emiliano Spezi Pavel Solny Pablo Minguez Gabina Francesco Cicone Caroline Stokke Carlo Chiesa Maria Paphiti Boudewijn Brans Mattias Sandström Jill Tipping Mark Konijnenberg Glenn Flux

BACKGROUND Currently, the implementation of dosimetry in molecular radiotherapy (MRT) is not well investigated, and in view of the Council Directive (2013/59/Euratom), there is a need to understand the current availability of dosimetry-based MRT in clinical practice and research studies. The aim of this study was to assess the current practice of MRT and dosimetry across European countries. M...

Journal: :Medical Dosimetry 2021

The purpose of this study was to evaluate whether dose the skin surface underneath bolus, accurately predicted by a 3D treatment planning system (TPS) in patients receiving 50 Gy/25# postmastectomy radiotherapy (PMRT) using optically stimulated luminescent dosimetry (OSLD) for verification. In vivo OSLDs performed 20 consecutive PMRT. An array 9 were applied chest wall or neobreast grid arrange...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید