نتایج جستجو برای: anthropomorphic phantom
تعداد نتایج: 19149 فیلتر نتایج به سال:
The image-guided CyberKnife radiosurgery system is apable of tracking spinal targets without fiducial implants. Recently, a new version of this fiducial-free image guidance modality ("enhanced Xsight spine tracking") has been introduced. We assessed the accuracy of this novel technique versus its precursor in a comparative phantom study. The CyberKnife consists of a 6 MV linac on a six-axis rob...
Worldwide harmonization of SAR compliance testing methodologies have led to changes from previously used procedure and equipment. This study focuses on the impact of the introduction of the Specific Anthropomorphic Mannequin (SAM) phantom, different dielectric properties of the tissue simulating liquid, and the 15 degree tilt device position on SAR measurement. The assessment was performed usin...
A method of feature extraction based on principal component analysis (PCA) to identify drugs packed in anthropomorphic phantom was proposed. An energy dispersive X-ray diffraction spectrometer was used to acquire the spectra of drugs and the other materials. Features of spectra were extracted by PCA which excels in analyzing highdimensional data. Furthermore, the number of principal components ...
An evaluation of two anthropomorphic breast phantoms, which have been designed for quality assurance and dose verification of radiotherapy treatment of breast cancer patients, is presented. These phantoms are identical in terms of their dimensions and shape, and composed of several layers of either Plastic Water or tissue-equivalent material. Both water- and tissue-equivalent phantoms include l...
We evaluated the accuracy of coronary artery calcium (CAC) scoring on a dual-source photon-counting detector CT (PCD-CT). An anthropomorphic chest phantom underwent ECG-gated sequential scanning PCD-CT at 120 kV with four radiation dose levels (CTDIvol, 2.0–8.6 mGy). Polychromatic images (T3D) and virtual monoenergetic (VMI), from 60 to 75 keV without quantum iterative reconstruction (no QIR) Q...
Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....
The purpose of this study is to characterize the x-ray properties of a dual-modality, anthropomorphic breast phantom whose MRI properties have been previously evaluated. The goal of this phantom is to provide a platform for optimization and standardization of two- and three-dimensional x-ray and MRI breast imaging modalities for the purpose of lesion detection and discrimination. The phantom is...
Background and purpose: The human body is composed of various inhomogenous tissues with a variety of physical and radiological properties. These inhomogeneities could change isodose distributions, increase the probability of geometric errors, and eventually lead to missing of the target irradiation or incorrect isodose coverage in conformal radiation therapy (CRT) due to the uncertainties resul...
orthopantomography is a well-established imaging technique in dental diagnosis. although its exposure to individuals is relatively low compared to other diagnostic radiology examinations, it is still the most frequent x-ray examination. so it is important to estimate absorbed dose to critical organs in this examination. the present study was designed to determine the radiation doses to eyes, pa...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید