نتایج جستجو برای: anodized titanium

تعداد نتایج: 36880  

Journal: :ACS applied materials & interfaces 2010
Yajun Ji Keng-Chu Lin Hegen Zheng Chung-Chiun Liu Laurie Dudik Junjie Zhu Clemens Burda

Transparent photocatalytic surfaces are of ever increasing importance for many applications on self-cleaning windows and tiles in everyday applications. Here, we report the formation and photocatalytic testing of a quasi-transparent thin and nanoporous titania films deposited on glass plates. Sputtered Ti thin films were anodized in fluoride-ion-containing neutral electrolytes to form optically...

2012
Panpan Wang Weijian Dai Lei Ge Mei Yan Shenguang Ge Jinghua Yu

The Ti foil (0.1 mm thickness, 99.6 % purity, Goodfellow, England) was cleaned by using distilled water and acetone and dried off with N 2 gas. The bare Ti foil was anodized in an ethylene glycol solution containing NH 4 F (0.38 wt%) and H 2 O (1.79 wt%) and placed in a well-insulated bath for 3 h at 30 V and at 20 ℃ using a dc power supply (N5753A model, Agilent). The textured Ti surface was o...

2014
Camilla Christian Gomes Moura Darceny Zanetta-Barbosa Paula Dechichi Valessa Florindo Carvalho

evaluated the effects of bio-anodized, acid-etched, and machined titanium surfaces (Ti) on Mφ behavior. Cells were separated from whole human blood from 10 patients, plated on Ti or polystyrene (control) surfaces, and cultured for 72 h. At 24, 48 and 72 h, cell viability, levels of IL1β, IL10, TNFα, TGFβ1 inflammatory mediators, and nitric oxide (NO) release were analyzed by mitochondrial color...

2013
Jung-Bo Huh Jeong-Yeol Lee Young-Chan Jeon Sang-Wan Shin Jin-Soo Ahn Jae-Jun Ryu

PURPOSE The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation. MATERIALS AND METHODS Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical graf...

Journal: :The International journal of oral & maxillofacial implants 2009
Stephen F Balshi Glenn J Wolfinger Thomas J Balshi

PURPOSE This clinical study using a specific technique was carried out to determine the clinical effectiveness of zygomatic implants under an immediate loading protocol. MATERIALS AND METHODS All patients treated between May 2000 and October 2006 who received zygomatic implants were included in this retrospective analysis. All patients were treated using the same surgical and restorative prot...

2012
Hongbo Wei Shuyi Wu Zhihong Feng Wei Zhou Yan Dong Guofeng Wu Shizhu Bai Yimin Zhao

Infection and epithelial downgrowth are major problems associated with maxillofacial percutaneous implants. These complications are mainly due to the improper closure of the implant-skin interface. Therefore, designing a percutaneous implant that better promotes the formation of a stable soft tissue biologic seal around percutaneous sites is highly desirable. Additionally, the fibroblast has be...

Journal: :Analytical chemistry 2002
C Terashima Tata N Rao B V Sarada D A Tryk A Fujishima

Anodically pretreated diamond electrodes have been used for the detection of chlorophenols (CPs) in environmental water samples after high-performance liquid chromatographic (HPLC) separation. The anodization of as-deposited boron-doped polycrystalline diamond thin-film electrodes has enabled the stable determination of phenols over a wide concentration range. Prior to the HPLC analysis, a comp...

Fatemeh Marashi-Najafi Jafar khalil-Allafi, Leila Fathyunes,

In this study, calcium-phosphate (Ca-P) and graphene oxide (GO)/ calcium-phosphate (Ca-P) coatings were electrodeposited with different pulsed current densities on TiO2 nanotubes. Results showed that the co-electrodeposition rate in the presence of GO, especially at low current densities of 2 and 5 mA/cm2, significantly decreased. This might be due to the large size of GO sheets as compared to ...

2014
Minghui Zhao Jidong Li Yubao Li Jian Wang Yi Zuo Jiaxing Jiang Huanan Wang

The poor control of the adhesion of TiO2 nanotubes (TNTs) layers to a non-anodized titanium (Ti) substrate has limited their widespread application, because the stripping mechanism has not yet been revealed. Here, we report a novel method to control the detachment of TNTs by post-treatment of the as-fabricated samples in protic and aprotic solvents with different polarities. Post-treatment usin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید