نتایج جستجو برای: adsorptive stripping voltammetry
تعداد نتایج: 14956 فیلتر نتایج به سال:
Copper and arsenic have been analysed in refined beet sugar at the microgram kg-1 level by anodic stripping voltammetry (copper) and cathodic stripping voltammetry (arsenic) in the differential-pulse mode (DPASV and DPCSV) at a hanging mercury drop electrode (HMDE). DPCSV measurements of arsenic are based on its accumulation onto the HMDE as an intermetallic Cu-As compound followed by the reduc...
A simple, precise, inexpensive and sensitive voltammetric method has been developed for the determination of gemifloxacin mesylate (GEM) in the presence of tween 80 in the bulk, farmaceutical dosage forms and human urine at gold nanoparticles modified carbon paste electrode (GNCPE). The electrochemical behavior of GEM has been investigated by using cyclic voltammetry (CV) and differential pulse...
17α-Ethinyl estradiol (EE2), which is used worldwide in the treatment of some cancers and as a contraceptive, is often found in aquatic systems and is considered a pharmaceutically active compound (PhACs) in the environment. Current methods for the determination of this compound, such as chromatography, are expensive and lengthy and require large amounts of toxic organic solvents. In this work,...
Cyclic voltammetry and differential pulse voltammetry were used to explore the adsorption behavior of three antibacterial agents at a carbon paste electrode. The drugs were accumulated on a carbon paste electrode, and a well-defined oxidation peak was obtained in acetate buffer (pH 5.0). The adsorptive stripping response was evaluated as a function of some variables such as the scan rate, pH an...
An easy, rapid and selective adsorptive stripping voltammetry (AdSV) method for the determination of vincamine in its formulation and human serum was developed and validated. It was based on the oxidation of the drug onto a Nujol-based carbon paste electrode. The stripping step was carried out by using a square-wave (SW) potential-time voltammetric excitation signal. The optimal experimental va...
The electrochemical behavior of thioctic acid at the hanging mercury drop electrode was studied in different supporting electrolytes. In Britton - Robinson buffer pH 3.29, the square - wave adsorptive anodic stripping voltammogram of thioctic acid exhibited a single well - defined anodic peak at about -0.21 V vs Ag/AgCl. The peak response was characterized with respect to pH, preconcentration t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید