نتایج جستجو برای: 3d gel dosimetry

تعداد نتایج: 299187  

2017
Lucas Persoon

Radiotherapy is one of the main treatment modalities to treat cancer. Image based treatment verification has been recently introduced. However, a quantitative comparison between the planned and delivered dose is a novel development in the field of radiotherapy. In this thesis, the added value of quantitative in-treatment dose measurements techniques to facilitate adaptive radiotherapy has been ...

Journal: :Medical physics 2000
D A Rajon D W Jokisch P W Patton A P Shah W E Bolch

An important problem in internal dosimetry is the assessment of energy deposition by beta particles within trabecular regions of the skeleton. Recent dosimetry methods for trabecular bone are based on Monte Carlo particle transport simulations within three-dimensional (3D) images of real human bone samples. Nuclear magnetic resonance (NMR) microscopy is a 3D imaging technique of choice due to t...

2014
Mohammad Bakhtiari Ashkan Parniani Fritz Lerma Shannon Reynolds James Jordan Alireza Sedaghat Mehrdad Sarfaraz James Rodgers

BACKGROUND Intensity modulated radiation therapy (IMRT) dosimetry verification is routinely conducted via integrated or individual field dosimetry using film or a matrix of detectors. Techniques and software systems are commercially available which use individual field dosimetry measurements as input into algorithms that estimate 3D patient dose distributions on CT scan derived target volumes a...

2006
Panagiotis Sandilos Elias Tatsis Lampros Vlachos Constantinos Dardoufas Pantelis Karaiskos Evangelos Georgiou Panagiotis Baras Panagiotis Kipouros Michael Torrens Angelos Angelopoulos

The polymer gel-Magnetic Resonance Imaging (MRI) dosimetry technique was employed to evaluate the mechanical and dose delivery accuracy in Leksell gamma knife stereotactic radiosurgery for the treatment of multiple targets. Two different polymer gel dosimeter formulations that have been reported in the literature were prepared in-house. A plan for the treatment of four brain metastases (targets...

ژورنال: سنجش و ایمنی پرتو 2016

The object of this research is the investigation of carbon nanotube (CNT) distribution effect on electrical conductivity of polymer-CNT composite as dosimetry response of this system. Thus, electrical conductivity of this composite was simulated for aligned, homogenous, and agglomerated distributions in 2D, and 3D situations. The results of simulation were compared and validated by experimental...

2016
Mauro Vaiente Wladimir Molina Lila Carrizales Silva Rodolfo Figueroa Francisco Malano Pedro Pérez Mauricio Santibañez José Vedelago

Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue-equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, independence of dose rate and incident direction, as well as linear dose response. This work presents the development and characteri...

Journal: :Physics in medicine and biology 2014
S Dahdouh N Varsier A Serrurier J-P De la Plata J Anquez E D Angelini J Wiart I Bloch

Fetal dosimetry studies require the development of accurate numerical 3D models of the pregnant woman and the fetus. This paper proposes a 3D articulated fetal growth model covering the main phases of pregnancy and a pregnant woman model combining the utero-fetal structures and a deformable non-pregnant woman body envelope. The structures of interest were automatically or semi-automatically (de...

2014
Liliana Aranda-Lara Eugenio Torres-García Rigoberto Oros-Pantoja

The biological tissue has been mimicked and replaced by other materials, which have shown certain radiological similarity determined by attenuation coefficient (μ), density and atomic number. Specifically, in molecular imaging and radiation therapy have been developed multifunctional radiopharmaceuticals which contain beta/gamma and/or light emitters to chronic degenerative diseases treatment. ...

F Mianji, H Afarideh S J HosseiniAliabadi S M Hosseini Pooya

Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید