نتایج جستجو برای: دستگاه pentacam

تعداد نتایج: 31547  

2017
Hanan Mofty Khaled Alzahrani Fiona Carley Sophie Harper Arun Brahma Leon Au Debbie Morley M Chantal Hillarby

Purpose The purpose of this study was to assess UV corneal crosslinking (CXL) treatment outcomes for keratoconus by evaluating the corneal regularity in patients through follow-up using the Oculus Pentacam. Patients and methods A total of 18 eyes from CXL patients with keratoconus were studied before and after CXL treatment, and six eyes from six patients who were not treated with CXL served ...

Journal: :Current eye research 2011
Luisa Simo Mannion Cindy Tromans Clare O'Donnell

PURPOSE To compare the corneal volume in keratoconic and normal eyes to improve our understanding of the tissue distribution associated with the disease. MATERIALS AND METHOD The Oculus Pentacam tomographer (Oculus Inc., Wetzlar, Germany) was used to analyze the corneal volume contained within discs with diameters of 3, 5, 7, and 10 mm in 21 patients with keratoconus and 21 matched healthy co...

2017
Ivo Guber Colm McAlinden François Majo Ciara Bergin

Background Reaching a consensus on which parameters are most reliable at detecting progressive keratoconus patients with serial topography imaging is not evident. The aim of the study was to isolate the parameters best positioned to detect keratoconus progression using the Pentacam HR® measures based on the respective limits of repeatability and range of measurement. Method Using the Pentacam...

Journal: :Journal of cataract and refractive surgery 2008
Hema Shankar Deepa Taranath Chandramalar T Santhirathelagan Konrad Pesudovs

PURPOSE To comprehensively assess the reliability of automated Pentacam (Oculus, Inc.) measurements. SETTING Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia. METHODS Both eyes of 35 normal volunteers were tested twice on the same day by 2 different observers. All automated values were recorded, and manual analysis of topographic maps was performed only...

Journal: :journal of research in medical sciences 0
mohammad reza sedaghat associate professor, eye research center, school of medicine, mashhad university of medical sciences, mashhad, iran maria shareepor resident, department of ophthalmology, eye research center, school of medicine, mashhad university of medical sciences, mashhad, iran samira hassanzadeh optometrist, school of paramedicine, mashhad university of medical sciences, mashhad, iran mojtaba abrishami resident, department of ophthalmology, eye research center, school of medicine, mashhad university of medical sciences, mashhad, iran

normal 0 false false false en-us x-none ar-sa background : the aim of this study was to determine the correlation between corneal hysteresis (ch) and the corneal resistance factor (crf), which are both novel methods of analyzing ocular rigidity/elasticity, and various corneal characteristics, mainly corneal volume in normal subjects. methods : this cross-sectional study included 500 normal eyes...

Journal: :Investigative ophthalmology & visual science 2015
Priya L Dabasia David F Edgar Ian E Murdoch John G Lawrenson

PURPOSE Comparing diagnostic accuracy of biomicroscope techniques (van Herick and Smith's tests, evaluating limbal and central anterior chamber depth, respectively) and advanced imaging (Visante OCT and Pentacam) for detection of gonioscopically narrow anterior chamber angles (ACAs). METHODS A total of 78 subjects with narrow or open ACAs underwent four index tests, performed on both eyes by ...

2016
Mun Yueh Faria Nuno Ferreira Eliana Neto

OBJECTIVE To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL) in ectopia lentis in Marfan syndrome (MFS). DESIGN Retrospective study. METHODS Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmol...

Journal: :Journal of refractive surgery 2009
Patricia Rosales Susana Marcos

PURPOSE To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). METHODS Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not...