Journal: :British heart journal 1986
Y Zhang S Nitter-Hauge H Ihlen K Rootwelt E Myhre

In an attempt to develop a new approach to the non-invasive measurement of aortic regurgitation, transmitral volumetric flow (MF) and left ventricular total stroke volume (SV) were measured by Doppler and cross sectional echocardiography in 23 patients without aortic valve disease (group A) and in 26 patients with aortic regurgitation (group B). The transmitral volumetric flow was obtained by m...

Journal: :Journal of veterinary emergency and critical care 2011
Ruth I McDevitt Craig G Ruaux Wendy I Baltzer

OBJECTIVE To determine the effect of 3 differing transfusion techniques on survival of autologous canine RBCs. DESIGN Prospective, blinded study. SETTING University Teaching Hospital. ANIMALS Nine healthy dogs. INTERVENTIONS Three distinct preparations of RBCs, each representing ~1% of red cell mass, were generated for each dog by biotinylation of RBCs at varying biotin densities. Label...

2014
P. Grolier Patrice GROLIER

This paper proposes a method of evaluating the performance of reciprocating compressors. An analytical formula of the volumetric efficiency is presented. This formula, based on both theoretical and empirical approach, takes account of the most important factors, which occur during the working process of the compressor and affect the refrigeration performance. An accurate determination of the cl...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 2012
Richard Camilli Daniela Di Iorio Andrew Bowen Christopher M Reddy Alexandra H Techet Dana R Yoerger Louis L Whitcomb Jeffrey S Seewald Sean P Sylva Judith Fenwick

On May 31, 2010, a direct acoustic measurement method was used to quantify fluid leakage rate from the Deepwater Horizon Macondo well prior to removal of its broken riser. This method utilized an acoustic imaging sonar and acoustic Doppler sonar operating onboard a remotely operated vehicle for noncontact measurement of flow cross-section and velocity from the well's two leak sites. Over 2,500 ...

Journal: :The Journal of experimental biology 2015
Deepak Adhikari Brad J Gemmell Michael P Hallberg Ellen K Longmire Edward J Buskey

We describe an automated, volumetric particle image velocimetry (PIV) and tracking method that measures time-resolved, 3D zooplankton trajectories and surrounding volumetric fluid velocity fields simultaneously and non-intrusively. The method is demonstrated for groups of copepods flowing past a wall-mounted cylinder. We show that copepods execute escape responses when subjected to a strain rat...

Journal: :تحقیقات موتور 0
ابوالفضل محمدابراهیم a. mohammadebrahim امیر حسین کاکایی a.h. kakaee

the objective of this work was to develop a new design of an intake manifold through a 1d simulation. it is quite familiar that a duly designed intake manifold is essential for the optimal performance of an internal combustion engine. air flow inside the intake manifold is one of the important factors, which governs the engine performance and emissions. hence the flow phenomenon inside the inta...

2001
Christopher Juneson Owen P. Ward Ajay Singh

Microbial treatment of bis(2-ethylhexyl)phthalate (BEHP) contaminated soil was evaluated in batch and sequencing batch reactors (SBR) using a mixed bacterial culture isolated from a BEHP-contaminated site. The BEHP-degrading mixed culture had three predominant component strains, Bre ibacterium iodinum, Rhodococcus luteus and Bacillus bre is. For soil slurry SBR studies, the hydraulic residence ...

2012
H. A. Gasim S. R. M. Kutty

Petroleum refineries discharged large amount of wastewater -during the refining processthat contains hazardous constituents that is hard to degrade. Anaerobic treatment process is well known as an efficient method to degrade high strength wastewaters. Up-flow Anaerobic Sludge Blanker (UASB) is a common process used for various wastewater treatments. Two UASB reactors were set up and operated in...

2011
Dae Yu Kim Jeff Fingler John S. Werner Daniel M. Schwartz Scott E. Fraser Robert J. Zawadzki

We present high-speed Fourier-domain optical coherence tomography (Fd-OCT) with the phase variance based motion contrast method for visualizing retinal micro-circulation in vivo. This technique allows non-invasive visualization of a two-dimensional retinal perfusion map and concurrent volumetric morphology of retinal microvasculature with high sensitivity. The high-speed acquisition rate at 125...

2014
Hong Qi Li Li Wen Jin Hongqi Li Liwen Jin

A single screw compressor is usually sealed by means of its tiny clearances. The theoretical research and the practice application shown that the leakage in the working process is always the key factor influencing the performance of this kind of compressor. Besides meeting the need of lubrication, the oil injection can greatly improve the sealing effect. It is obvious that the reduction of clea...