نتایج جستجو برای: trochanteric fractures

تعداد نتایج: 60132  

Journal: :The Cochrane database of systematic reviews 2005
Martyn J Parker Helen H G Handoll

BACKGROUND Two types of implants used for the surgical fixation of extracapsular hip fractures are cephalocondylic intramedullary nails, which are inserted into the femoral canal proximally to distally across the fracture, and extramedullary implants (e.g. the sliding hip screw). OBJECTIVES To compare cephalocondylic intramedullary nails with extramedullary implants for extracapsular hip frac...

سهیلی‌آزاد, علی‌اکبر, یاوری, هوتن, اعظمی, مریم ,

    Background & Objective: Osteoprosis is the most frequent underlying cause of femoral neck fractures in the eldery. These fractures weigh heavily on health care budgets. An accurate and exhaustive evaluation of these costs would be a major contribution to health economic studies evaluating the efficiency of screening and preventive strategies. However, in Iran, very little data on the financ...

Journal: :Collegium antropologicum 2008
Josip Turcić Ivan Dobrić Tonisav Antoljak

The goal of this research was to find the implant which would provide a better possibility of the fractured osteoporotic bone weight bearing after trochanteric fracture fixation. The authors constructed a new implant based on the conventional condylar plate, as part of a stabile triangular system. Because of the special oblique form of the screw which absolutely stabilizes vertical and horizont...

2017
Joong-Myung Lee Yongsuk Cho Junhyun Kim Dong-Won Kim

PURPOSE Femoral intertrochanteric fractures are common in the elderly. Appropriate surgical fixation of trochanteric fracture fragments can restore normal anatomical structure and ambulation, and can aid in the recovery of biomechanical function of the hip. We evaluated clinical outcomes of bipolar hemiarthroplasty using a wiring technique for trochanteric fracture fragment fixation. MATERIAL...

Journal: :The Journal of bone and joint surgery. British volume 2005
C A Busch M N Charles C M Haydon R B Bourne C H Rorabeck S J Macdonald R W McCalden

We identified five (2.3%) fractures of the stem in a series of 219 revision procedures using a cementless, cylindrical, extensively porous-coated, distally-fixed femoral stem. Factors relating to the patients, the implant and the operations were compared with those with intact stems. Finite-element analysis was performed on two of the fractured implants. Factors associated with fracture of the ...

Journal: :Orthopedics 2015
Alessandro Calistri Catherine Van der Straeten Koen De Smet

Adverse reaction to metal debris (ARMD) involving the hip joint has emerged as an important reason for failure and revision among patients with metal-on-metal (MOM) hip arthroplasty. To the authors' knowledge, there are no reports of adverse radiographic sequelae in the greater trochanter subsequent to revision for ARMD. The authors describe clinical and radiographic findings in 2 patients who ...

Journal: :Acta orthopaedica Belgica 2012
Philip Winnock de Grave Thomas Tampere Pieter Byn John Van Overschelde Christophe Pattyn René Verdonk

We report the results of a prospective randomized clinical trial comparing the Gamma 3 nail with the ACE trochanteric nail for the treatment of pertrochanteric femoral fractures. One hundred and twelve consecutive patients were enrolled in the study: 61 patients were treated with the Gamma 3 nail, 51 with the ACE trochanteric nail. The two groups were matched for age, fracture type and preopera...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید