2013
Jin Wang Zhongping Yang Fei Lin

The traction transformer of the traction drive system of a high-speed train is one of the main equipments for energy conversion. The transformer loss will be increased by load harmonics and pantograph arcs at high speed. It is very important to predict losses for the improvement of traction transformer design. In this paper, a dynamic model of the pantograph-catenary system is established using...

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

2012
Ali Naderian

This study adopted previous fault patterns, results of detection analysis, historical records and data, and experts’ experiences to establish fuzzy principles and estimate the failure probability index of components of a power transformer. Considering that actual parameters and limiting conditions of parameters may differ, this study used the standard data of IEC, IEEE, and CIGRE as condition p...

2015
P. Mercy N. Uma Maheswari S. Deepika Devi V. Dhamodharan

Abstract: Power transformers are one of the most important electrical equipment that are used in power transmission system as they perform the function of transforming the voltage levels. Hence maintenance of power transformer is mandatory; as they are located at different geographical areas periodical monitoring is not possible all the time due to insufficient man power. Due to this reason tra...

2013
S. Jamali Arand

The inrush current is a transient current that results from a sudden change in the exciting voltage across a transformer’s windings. It may cause inadvertent operation of the protective relay system and necessitate strengthening of the transformer’s mechanical structure. Many methods were reported in the literatures for reduction and mitigation of transformer inrush currents. This paper represe...

2013
Cui-fen Bai Wen-Sheng Gao Tong Liu

Regression analysis is applied to quantitatively analyze the impact of different ambient temperature characteristics on the transformer life at different locations of Chinese mainland. 200 typical locations in Chinese mainland are selected for the study. They are specially divided into six regions so that the subsequent analysis can be done in a regional context. For each region, the local hist...

2018
Hazlee Azil Illias Wee Zhao Liang

Early detection of power transformer fault is important because it can reduce the maintenance cost of the transformer and it can ensure continuous electricity supply in power systems. Dissolved Gas Analysis (DGA) technique is commonly used to identify oil-filled power transformer fault type but utilisation of artificial intelligence method with optimisation methods has shown convincing results....

2014
Ankush Chander

Reliable and continued performance of power Transformer is the key to profitable generation and transmission of electric power. Failure of a large power transformer not only results in the loss of very expensive equipment, but it can cause significant guarantied damage as well. Replacement of that transformer can take up to a year if the failure is not disastrous and can result in tremendous re...

2012
Zhimin He Yadong Liu Jing Chen Wanjian Bai Gehao Sheng Xiuchen Jiang

The effective assessment on the operation condition of power transformer is an important means to conduct the condition maintenance for transformer and to improve the reliability of power system. Based on the amount of information of all kinds of online monitoring conditions obtained from the transformer intelligent components, the assessment model for comprehensive condition of transformer is ...

2013
Yang Yongming Duan Xu

A real time on-line transformer vibration monitoring system based on the Labview is proposed and applied in the monitoring of abnormal vibration of transformer caused by DC bias in this paper. The monitoring of the transformer body vibration and the signal online analysis can be well performed by this system. The vibration signals of the transformer body are detected by three acceleration senso...