نتایج جستجو برای: stapedotomy
تعداد نتایج: 185 فیلتر نتایج به سال:
Monaural hearing induces auditory system reorganization. Imbalanced input also degrades time-intensity cues for sound localization and signal segregation for listening in noise. While there have been studies of bilateral auditory deprivation and later hearing restoration (e.g., cochlear implants), less is known about unilateral auditory deprivation and subsequent hearing improvement. We investi...
INTRODUCTION Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis. MATERIALS AND METHODS A total of 57 ears were included ...
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation w...
OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTIO...
Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis. Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were rev...
Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis. Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were...
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation w...
OBJECTIVE Beta-trace protein (beta-TP) has been analysed in human cerebrospinal fluid (CSF) and other body fluids. Beta-trace protein is a very sensitive and specific clinical marker and can confirm reliably the presence of CSF in patients with a suspected CSF leakage. DESIGN Perilymph specimens from the scala vestibuli (n=10) and from the lateral semicircular canal (n=4) were taken from pati...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید