نتایج جستجو برای: spiral tomography
تعداد نتایج: 202719 فیلتر نتایج به سال:
The accuracy of computed tomography (CT) imaging for the diagnosis of acute pulmonary embolism (PE) was reviewed. Single detector CT, based on pooled data, showed a sensitivity of 73% and multidetector CT, mostly 4-slice, showed a sensitivity of 83%. Respective specificities were 87% and 96%. Among patients with suspected PE evaluated with single slice CT, 20% of patients found to have venous t...
We report a case of 50-year-old man who was presented with recurrent episodes of left sided hemiparesis. CT scan and MRI brain revealed a large intraventricular fatty lesion. Histopathological examination showed a picture of angiolipoma.
A62-year-old man presented to our emergency room with severe retrosternal pain. An ECG showed an acute lateral myocardial infarction, and the patient was referred for cardiac catheterization. One and a half hours after the onset of acute chest pain, coronary angiography revealed a thrombotic occlusion of the intermedial branch of the left coronary artery. Mechanical recanalization of the infarc...
L ast year, the New England Journal of Medicine ran a lead article reporting that patients with lung cancer had a 10-year survival approaching 90% if detected by screening spiral computed tomography. The publication garnered considerable media attention, and some felt that its findings provided a persuasive case for the immediate initiation of lung cancer screening. We strongly disagree. In thi...
BACKGROUND The sample size required to power a study to a nominal level in a paired comparative diagnostic accuracy study, i.e. studies in which the diagnostic accuracy of two testing procedures is compared relative to a gold standard, depends on the conditional dependence between the two tests - the lower the dependence the greater the sample size required. A priori, we usually do not know the...
Although the excellent spatial resolution of multislice spiral computed tomography (MSCT) enables the coronary arteries to be visualized, its limited temporal resolution results in poor image reproducibility because of cardiac motion artifact (CMA) and hence limits its widespread clinical use. A novel retrospectively ECG-gated reconstruction method has been developed to minimize CMA. In 88 cons...
The poor prognosis of lung cancer has barely changed in the last decades, but the prognosis is better when the disease is detected earlier. Lung cancer screening by chest radiography did not lead to a decrease in lung cancer mortality, presumably because the chest radiograph is a poor screening tool with low sensitivity. With the advent of the low-dose spiral computed tomography (CT) scan it ha...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید