Shahriar Shahi Hadi Mokhtari Saeed Rahimi Vahab Shiezadeh Habib Ashasi Majid Abdolrahimi Mohammad Foroughreyhani

AIM The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. STUDY DESIGN A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted hum...

2015
Suparna Ganguly Saha Neelam Vijaywargiya Divya Saxena Mainak Kanti Saha Anuj Bharadwaj Sandeep Dubey

Introduction To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. T...

2017
Taha Özyürek Koray Yılmaz Gülşah Uslu

OBJECTIVES The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. MATERIALS AND METHODS Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with ...

2014
Fatma Asheibi Alison J.E. Qualtrough Anthony Mellor

The aim of this study was to investigate whether endodontically retreated teeth filled with Resilon are more resistant to fracture than those filled with guttapercha following hand or rotary removal techniques. Seventy-two upper anterior human teeth were selected, decoronated and reduced to 12 mm. The canals were shaped using rotary ProTaper files and randomly assigned into two groups (n=36). O...

Journal: :Journal of endodontics 2011
Luca Testarelli Gianluca Plotino Dina Al-Sudani Valentina Vincenzi Alessio Giansiracusa Nicola M Grande Gianluca Gambarini

INTRODUCTION The aim of the present study was to evaluate the bending properties of Hyflex instruments, which exhibit a lower percent in weight of nickel (52 Ni %wt) and compare them with other commercially available nickel-titanium (NiTi) rotary instruments. METHODS Ten instruments with tip size 25, 0.06 taper of each of the following NiTi rotary instrumentation techniques were selected for ...

Journal: :Journal of endodontics 2004
Najia Usman J Craig Baumgartner J Gordon Marshall

Files of Greater Taper (GT) are rotary nickel-titanium files of three tapers (0.06, 0.08, 0.10) with file tips of sizes 20, 30, and 40. The purpose of this study was to compare in an in situ model the efficacy of root canal debridement in the apical 3 mm when instrumenting to a GT size 20 or a GT size 40 at working length. Twenty matched human cadaver teeth with 32 canals were decoronated at th...

Journal: :journal of dentistry, tehran university of medical sciences 0
m. bidar s. moradi mh. zarrabi b. barikbin

statement of problem: various factors are involved in causing inflammation following root canal treatment. controlling these factors may relieve the related pain. one of these factors is extrusion of debris beyond the apex. although debris extrusion happens in all instrumentation techniques, researchers have declared that in coronal flaring technique, there is minimum debris extrusion. purpose:...

Journal: :iranian endodontic journal 0
narges farhad mollashahi eshagh ali saberi seyed rohollah havaei mohammad sabeti

introduction: root canal preparation techniques may cause postoperative pain. the aim of the present study was to compare the intensity of postoperative pain after endodontic treatment using hand files, single file rotary (oneshape), and single file reciprocating (reciproc) systems. methods and materials: in this single-blind, parallel-grouped randomized clinical trial a total of 150 healthy pa...

بشری, منا, تاپاک, لیلی, سالمی, فاطمه, شکری, عباس, کرکه‌آبادی, حامد,

Background and Objective: The preparation of the root canal (i.e., cleaning and shaping) is the main step in the endodontic treatment. The nickel-titanium rotary files result in fewer errors during the preparation of curved canals. This study aimed to compare the transportation of Neolix and Reciproc rotary systems in curved canals using cone beam computed tomography (CBCT). Materials and Meth...

Ali Akbar Haghdoost Arash Shahravan, Ghasem Sahranavard Masoud Parirokh, Zeynab Kazemizadeh

BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...