نتایج جستجو برای: pvc membrane electrode

تعداد نتایج: 452869  

2011
Eman Y. Z. Frag Gehad G. Mohamed Mohamed M. Khalil Mohammad M. A. Hwehy

This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fas...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Mohammad Reza Ganjali Mahnaz Abdi Hooshang Pirelahi Arash Mouradzadegun Mahmood Reza Sohrabi

A novel imidazole membrane sensor based on 2,4,6-triphenyl thiopyrilium perchlorate (TTP) as an excellent charged carrier, poly(vinyl chloride) (PVC), the plasticizer dibutyl phthalate (DBP) and oleic acid as an additive is described. The sensor responds to imidazole over a wide concentration range from 1.0 x 10(-5) to 1.0 x 10(-1) M with a slope of +33.5 +/- 0.5 mV per decade. The detection li...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2007
Hosny Ibrahim Amal Khorshid

A comparative study was made between developed chemically modified carbon paste electrodes and PVC membrane electrodes for the cationic surfactant cetyltrimethylammonium bromide (CTAB). The carbon paste electrode modified with cetyltrimethylammonium-tetrachloropalladate(II) (CTA-TClP) provides a more sensitive and stable device than that shown by electrodes with an inner reference solution. The...

In this work, polyvinylchloride (PVC) membrane prepared via casting solution technique and phase inversion method. N, N dimethylacetamide (DMAC) was used as primary solvent and Tetrahydrofuran (THF) was used as a co-solvent. The effects of parameters such as membrane thickness, evaporation time of casting film before immersion precipitation and addition of polyethylenglchol (PEG) on PVC membran...

پایان نامه :دانشگاه تربیت معلم - تهران - دانشکده شیمی 1387

چکیده ندارد.

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه علوم پایه دامغان - دانشکده شیمی 1387

چکیده ندارد.

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

2012
Tahereh Poursaberi

Combination of the exceptional properties of graphene oxide with the selectivity of lead porphyrin leads to fabricate a novel cysteine-selective sensor. The electrode made of 30% PVC, 53% NPOE, 2% NaTPB and 15% GO-PP was found to show the most favorable behavior. The sensor shows a Nernstian response (58.8 mV decade) in the concentration window of 5.0×10-5.0×10 M with detection limit of 8.0×10 ...

2004
Ajay K. Jain Vinod K. Gupta Jitendra R. Raisoni

Membranes of 4-tert-butylcalix(8)arene-octaacetic acid octaethyl ester (I) as an electroactive material, sodium tetraphenyl borate (NaTPB) as an anion excluder, and tri-n-butyl phosphate (TBP) as a solvent mediator in poly(vinyl chloride) (PVC) matrix have been tried for a strontium-selective sensor. The best performance was exhibited by the membrane having a composition 5:100:150:2 (I: PVC: TB...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید