نتایج جستجو برای: proximal femoral fracture

تعداد نتایج: 189639  

Journal: :Acta orthopaedica Belgica 2010
Mathew D Sewell Sammy A Hanna Richard W Carrington Robin C Pollock John A Skinner Stephen R Cannon Timothy W R Briggs

Addressing severe proximal femoral bone loss in revision hip surgery is a challenging reconstructive problem. The use of modular proximal femoral megaprostheses is one of many available options to address this. This is a retrospective review of 15 patients who had undergone limb salvage at our institution using a modular proximal femoral replacement. There were 8 males and 7 females with a mean...

Journal: :مجله پزشکی ارومیه 0
نسرین نوایی فر nasrin navaeifar orthopedic surgery department, imam khomeini hospital, urmia university of medical sciences, urmia, iranارومیه، دانشگاه علوم پزشکی ارومیه، مرکز آموزشی و درمانی امام خمینی (ره)، تلفن: 09111358426سازمان اصلی تایید شده: دانشگاه علوم پزشکی ارومیه (urmia university of medical sciences) فردین میرزاطلوعی fardin mirzatolouei professor,orthopedic surgery department, faculty of medicine, imam khomeini hospital, urmia university of medical sciences, urmia, iranاستاد ارتوپدی، دانشگاه علوم پزشکی ارومیه، ارومیه، ایرانسازمان اصلی تایید شده: دانشگاه علوم پزشکی ارومیه (urmia university of medical sciences) فائز باقری faez bagheri orthopedic surgery department, faculty of medicine, imam khomeini hospital, urmia university of medical sciences, urmia, iranدانشگاه علوم پزشکی ارومیه، ارومیه، ایرانسازمان اصلی تایید شده: دانشگاه علوم پزشکی ارومیه (urmia university of medical sciences)

abstract we report a 71 year-old patient with intertrochanteric fracture who had been managed with dhs and her healed fracture complicated by a subcapital femoral neck fracture. a subcapital femoral neck fracture complicating a healed intertrochanteric fracture is rare but catastrophic event. such cases are managed in a hetereogenous manner, i.e. there exists a mixture of cases treated by eithe...

Journal: :Bone 1999
P Kannus J Parkkari J Poutala

The purpose of this in vitro biomechanical study is to determine the force attenuation capacity of four different hip protectors (KPH1, KPH2, Safehip, and Safetypants) in falling simulations in elderly subjects (falls to the side). The simulated falling conditions were created by a biomechanical testing system, which consisted of an impact pendulum, surrogate pelvis and femur, and two load cell...

2014
Chandra Prakash Pal Pulkesh Singh Deepak Kumar Arpit Singh

INTRODUCTION Fractures involving bones containing a component of a prosthetic joint are becoming more common. The causation is multifactorial but most of these injuries are associated with trivial trauma. The options available for operative management of these fractures include internal fixation of the fracture alone, fixation of the fracture with revision of the prosthesis, and reconstruction ...

Journal: :iranian journal of radiology 0
hui-zhao wu department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china mahrukh latif department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china zhi-wei zhong department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china bao-hai yu department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china wen-juan wu department of radiology, the third hospital of hebei medical university, hebei province biomechanical key laboratory of orthopedics, shijiazhuang, china; department of radiology, the third hospital of hebei medical university, no.139, ziqiang road, shijiazhuang, 050051, china. tel: +86-31188603366, fax: +86-31187023626 feng zhang department of rehabilitation medicine, the third hospital of hebei medical university, shijiazhuang, china

conclusion dt-sfp can improve the detection of relatively early bone abnormalities in acetabular and proximal femur compared with conventional radiography. dt-sfp can also observe the abnormal impact between acetabular and proximal femur. patients and methods ninety-four consecutive patients with discomfort around the hip joint underwent dt-sfp and conventional radiography. the imaging features...

2016
Nikolai Briffa Raju Karthickeyan Joshua Jacob Arshad Khaleel

The aim of this study was to compare the biomechanical properties of medial and lateral plating of a medially comminuted supracondylar femoral fracture. A supracondylar femoral fracture model comparing two fixation methods was tested cyclically in axial loading. One-centimetre supracondylar gap osteotomies were created in six synthetic femurs approximately 6 cm proximal to the knee joint. There...

Journal: :Journal of orthopaedic surgery 2009
Haruka Kaneko Keiji Matsuda Sungon Kim Kouichi Maeda Takashi Ikegami Reiko Kubota Masataka Nagayama Masahiko Nozawa

Subcapital femoral neck fractures are a rare complication after fixation of an intertrochanteric fracture with a proximal femoral nail. We report 2 such cases where the patients had severe osteoporosis, based on Singh's index and pathological findings. In one case there was a technical error leading to a tip-apex distance of more than 20 mm, but osteoporosis appeared to be a more significant ca...

2014
Kun-Jhih Lin Hung-Wen Wei Kang-Ping Lin Cheng-Lun Tsai Pei-Yuan Lee

Adequately shaped femoral plate is critical for the fixation of fracture in the pertrochanteric regions. Lateral aspect of greater trochanter is an important region where the proximal femoral plate anchored. However, little is known regarding the morphology of greater trochanter. The objective of this study was to measure main dimensions of greater trochanter and other regions in the proximal e...

Journal: :Journal of orthopaedic surgery 2009
Himanshu Kataria Neeraj Sharma Rajesh Kumar Kanojia

We report a case where a one-stage osteotomy and fixation, using a long proximal femoral nail and fibular graft, was performed to correct a severe shepherd's crook deformity (70-degree varus and 50-degree retroversion) of the femoral neck with a pathological stress fracture in a patient with fibrous dysplasia. The neck shaft angle was corrected to 125 degrees. At the 57-month follow-up, the pat...

2017
Takayuki Tsuda

Fragility fractures in the elderly is an ongoing concern for orthopaedic surgeons. A 50-year-old woman has a 40% chance of having a vertebral compression fracture in her lifetime. The incidence of vertebral fractures, reported to be more than 10 times higher than that of femoral fractures, is estimated as 1-1.5 million per year in Japan. Vertebral fractures often occur without a fall, whereas t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید