نتایج جستجو برای: potentiometry
تعداد نتایج: 516 فیلتر نتایج به سال:
It is important to have accurate, reliable, and convenient techniques for determining the methanol crossover rate through the polymer electrolyte membranes of fuel cells. In this work, various electrochemical techniques, namely; cyclic voltammetry, chronoamperometry and potentiometry, have been used to measure the methanol crossover rates using Nafion 117 membrane. The purpose of using differen...
The complex formation between a cyclic ligand glutarimidoxioxime (denoted as HL(III) in this paper) and UO2(2+) is studied by potentiometry and microcalorimetry. Glutarimidoxioxime (HL(III)), together with glutarimidedioxime (H2L(I)) and glutardiamidoxime (H2L(II)), belongs to a family of amidoxime derivatives with prospective applications as binding agents for the recovery of uranium from seaw...
In this paper, we design and implement a portable potentiostat by using dual-microprocessors for the signal processing of electrochemical biosensors. In our design approach, one of the microprocessors is used to design the programmable waveform generator, and the other microprocessor is used to measure the current of biosensors. The proposed potentiostat can perform general electrochemical anal...
Thermodynamic parameters of complex formation between d(10) metal ions, such as Zn(2+), Cd(2+), Hg(2+) and Ag(+), and the macrocyclic thioether 1,4,7-trithiacyclononane ([9]AneS3) or the monodentate diethylsulfide (Et(2)S), in acetonitrile (AN) at 298.15 K, were studied by a systematic methodology including potentiometry, calorimetry and polarography. [9]AneS3 is able to form complexes with all...
the preparation of polymer membrane selective to iron(ii) ion and its application to ion-selectiveelectrode is reported here. pvc membrane contains iron–selective n-phenylaza-15-crown-5 asionophore. the membrane electrode is highly selective to iron(ii) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 m with nernstian slope of29.2 ± 0.6 mv per deca...
we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...
in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...
a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two mont...
A method based on microwave-induced combustion (MIC) was applied for medicinal plants digestion allowing further chlorine determination by potentiometry using ion-selective electrode (ISE). Sample masses ranging from 500 to 1000 mg were evaluated MIC digestion. Water and 10, 25, 50, 100 mmol/L NH4OH investigated as absorbing solutions. The accuracy of the proposed certified reference materials ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید