Hemma Philamore Jonathan Rossiter Ioannis Ieropoulos

We present an energetically autonomous robotic tadpole that uses a single membrane component for both electrical energy generation and propulsive actuation. The coupling of this small bio-inspired power source to a bio-inspired actuator demonstrates the first generation design for an energetically autonomous swimming robot consisting of a single membrane. An ionic polymer metal composite (IPMC)...

H. Aghaie M. Giahi M. Zawari

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

Contact resistance among the components of a polymer exchange membrane fuel cell (PEMFC) has a crucial effect on cell performance. The geometry of the endplate plays an essential role in the contact pressure distribution over the membrane electrode assembly (MEA) and the amount of contact resistance between plates. In this work, the effects of endplate geometry on the contact pressure distribut...

Journal: :physical chemistry and electrochemistry 0

polypyrrole (ppy) nanofibers have been fabricated on glassy carbon electrode (gce) usingelectrochemical technique. electropolymerization of pyrrole (py) for the fabrication of ppy nanofiberswas occurred on gce by applying a fixed potential of about 0.85 v for 120 sec in a mild basic solutioncontaining sodium carbonate and sodium perchlorate. in the mild basic media, the monomer, py, isoxidized ...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2008
mohammad hosseini baharak bahmani fatollah moztarzadeh mohammad rabiee

in this research, an enzyme modified electrode has been produced during the electropolymerization of aniline through incorporation of sulfite oxidase into a conducting polymer. then the bioelectrochemical response of resulted sulfite biosensor was investigated at different experimental conditions. study of  the stability of the resulted sulfite biosensor revealed that formation of a passive fil...

Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...

Forogh Adhami Leila Hajiaghababaei Saeid Takalou

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

Journal: :Analytical chemistry 2011
Glen D O'Neil Raluca Buiculescu Samuel P Kounaves Nikos A Chaniotakis

There is currently a need for a reliable solid-state reference electrode, especially in applications such as autonomous sensing or long-term environmental monitoring. We present here for the first time a novel solid-state nanofiber junction reference electrode (NFJRE) incorporating a junction consisting of poly(methyl methacrylate) and carbon graphene stacked nanofibers. The NFJRE operates by u...

2016
Xiaoli Dong Long Chen Jingyuan Liu Servane Haller Yonggang Wang Yongyao Xia

Current rechargeable batteries generally display limited cycle life and slow electrode kinetics and contain environmentally unfriendly components. Furthermore, their operation depends on the redox reactions of metal elements. We present an original battery system that depends on the redox of I(-)/I3 (-) couple in liquid cathode and the reversible enolization in polyimide anode, accompanied by L...

Journal: :Biotechnology and bioengineering 1993
M E Meyerhoff M Trojanowicz B O Palsson

A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-g...