Polychromatic x-ray beams traveling though material are prone to beam hardening, i.e., the high energy part of the incident spectrum gets over represented when traveling farther into the material. This study discusses the concept of a mean attenuation coefficient in a formal way. The total energy fluence is one-to-one related to the traveled distance in case of a polychromatic beam moving throu...
The quantitative accuracy of SPECT is limited by photon attenuation and scatter effect when photons interact with atoms. In this study, we developed a new attenuation correction (AC) method, CT-based mean attenuation correction (CTMAC) method, and compared it with various methods that were often used currently to assess the AC phenomenon by using the small-animal SPECT/CT data that were acquire...
Generally, computerised tomography (CT) is an X-ray based non-destructive testing method that was developed for medical purposes in the seventies and introduced for industrial applications during the eighties. CT produces maps of the X-ray linear attenuation coefficient of an object’s interior; presented either as cross section images (two-dimensional CT) or as volume information (three-dimensi...
Citrine is a transparent gemstone, yellow microcrystalline quartz variety. Natural citrine is very rare and will actually lose its color upon heating to more than 200°C, and the yellow color will occur again when the crystal is irradiated with Xor gamma-rays, indicating that attenuation parameters is important to enhancements by irradiation. In this work, the mass attenuation coefficients of ci...
Artifacts are produced in 201TI cardiac single photon emission computed tomography (SPECT) imaging because of a variety of causes including soft-tissue attenuation, overlying abdominal viscera, variable myocardial thickness, left bundle branch block, cardiac rotation, patient motion, and technical errors. Careful attention to quality control, utilization of motion detectors, and familiarization...
We use an optical cavity to detect single atoms magnetically trapped on an atom chip. We implement the detection using both fluorescence into the cavity and atom-induced reduction in cavity transmission. In fluorescence, we register 2.0(2) photon counts per atom, which allows us to detect single atoms with 75% efficiency in 250 micros. In absorption, we measure transmission attenuation of 3.3(3...
The flux of neutrinos and photons originating from cosmic ray interactions with the interstellar medium in the galaxy is calculated based on current models for high energy particle interactions. The contribution from a possible dark matter halo of the galaxy is considered. The photon flux gets a non-trivial attenuation due to interactions with the cosmic background radiation. The neutrino fluxe...
BACKGROUND Soft tissue attenuation is a prominent cause of single-photon emission computed tomography (SPECT) imaging artifacts, which may result in reduced diagnostic accuracy of myocardial perfusion imaging. A method incorporating simultaneously acquired transmission data permits nonuniform attenuation correction and when incorporating scatter correction and resolution compensation may substa...
PET Center, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstrae 400, 01328 Dresden, Germany Combined PET/MR is a promising tool for simultaneous investigation of soft tissue morphology and function. However, contrary to CT, MR images do not provide information on photon attenuation in tissue. In the currently available systems issue is solv...