نتایج جستجو برای: nernstian response
تعداد نتایج: 977441 فیلتر نتایج به سال:
In the view of the complexities involved in the environmental cycling of hazardous metal species, attempts have been made to develop a poly (vinyl chloride) (PVC) based sensor for detection of MoO4 2ions using positively charged diaza crown ether (18-crown-6). The influence of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the per...
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anio...
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations and biological fluids (urine and serum). It was based on potentiometric titration of...
in this work, all-solid-state potentiometric pvc membrane sensor was introduced for fast andsimple monitoring of mercury ions in waste water samples. the all solid sate electrode is made based on aconductive composite of graphite, reduced graphene oxide, epoxy resin on a copper wire. a thin layer pvcmembrane is then coated on the surface of the new conducting transducer. pvc membrane is compose...
a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m with nernstian slope of 19.64 ± 0.15 mv decade-1...
The glass electrode is the most commonly used device to access the pH of an aqueous solution. It attains highly accurate measurements via simple and well-established procedures. However, the reasons why the glass electrode potential scales with hydrogen ion concentration according to almost Nernstian potential values have been long-standing challenges to explain. Only in the past 50 years has a...
This paper describes the design, fabrication, and validation of a paper-based diagnostic device for rapid diagnosis hypocalcemia in dairy cattle at point-of-care (POC). The incorporates 3D printed calcium ion-selective membrane (ISM) as sensing element free—unbound—calcium real bovine whole blood samples. With linear response range 100 mM to 97.7 ? M, sensor covers clinically relevant concentra...
A new highly selective iodide electrode incorporating a binuclear manganese(III) complex, bis(salicylaldehyde-aminopropanol)dichloroaceticdimanganese(III) [Mn(III)(2)-BSAPDCA], as a neutral carrier is described. The electrode displays an anti-Hofmeister selectivity sequence: iodide >> perchlorate > salicylate > thiocyanate > nitrate > bromide > nitrite > chloride > sulfate. The excellent select...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید