نتایج جستجو برای: mv photon beam

تعداد نتایج: 199565  

Journal: :Journal of Ayub Medical College, Abbottabad : JAMC 2010
Saeed Ahmad Buzdar M Afzal Andrew Todd-Pokropek

BACKGROUND In radiotherapy treatment, the calculation of radiation dose distribution in target volume lead to an optimum set of planning parameters. This worked has been aimed to compare two photon beam dose calculation algorithms in the Oncentra Treatment Planning system for Varian Linear Accelerator, to assure the quality of treatment planning. METHODS Monitor Units to be delivered on norma...

A. Ameri, A.R. Nikoofar, G. Esmaili, P. Fadavi, S.R. Mahdavi, V. Nazari,

Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All t...

2013
Lukkana Apipunyasopon Somyot Srisatit Nakorn Phaisangittisakul

The purpose of the study was to investigate the use of the equivalent square formula for determining the surface dose from a rectangular photon beam. A 6 MV therapeutic photon beam delivered from a Varian Clinac 23EX medical linear accelerator was modeled using the EGS4nrc Monte Carlo simulation package. It was then used to calculate the dose in the build-up region from both square and rectangu...

2017
Matthew A. Bolt Graham Bass Rebecca Nutbrown Tao Chen Andrew Nisbet Catharine H. Clark

Background and purpose: Audit is imperative in delivering consistent and safe radiotherapy and the UK has a strong history of radiotherapy audit. The National Physical Laboratory (NPL) has undertaken audit measurements since 1994 and this work examines results from these audits. Materials and methods: This paper reviews audit results from 209 separate beams from 82 on-site visits to National He...

2015
Isra Israngkul-Na-Ayuthaya Sivalee Suriyapee Phongpheath Pengvanich

A high-energy photon beam that is more than 10 MV can produce neutron contamination. Neutrons are generated by the [γ,n] reactions with a high-Z target material. The equivalent neutron dose and gamma dose from activation products have been estimated in a LINAC equipped with a 15-MV photon beam. A Monte Carlo simulation code was employed for neutron and photon dosimetry due to mixed beam. The ne...

Journal: :iranian journal of radiation research 0
n.n.a razak school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. rahman 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia s. kandaiya 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia i.s. mustafa 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia a.a. mahmoud 1school of physics, university sains malaysia, 18000, pulau pinang, malaysia n.z. yahaya school of distance education, university sains malaysia, 18000, pulau pinang, malaysia

background: an effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. materials and methods: the magat gel dosimeter formulations that used different compositions of methacrylic acid (maa) and gelatin were extensively investigated in the present study according to the r2–dose response and r2–dose sensitivity. the irradiation of magat gel was per...

H. Gharaati, K.N. Esnaashari, M. Allahverdi, M. Shahriari,

Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...

2017
Naoki Kinoshita Hiroshi Oguchi Yasuhiro Nishimoto Toshiki Adachi Hiroki Shioura Hirohiko Kimura Kunio Doi

The American Association of Physicists in Medicine (AAPM) Working Group on TG-51 published an Addendum to the AAPM's TG-51 protocol (Addendum to TG-51) in 2014, and the Japan Society of Medical Physics (JSMP) published a new dosimetry protocol JSMP 12 in 2012. In this study, we compared the absorbed dose to water determined at the reference depth for high-energy photon beams following the recom...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید