نتایج جستجو برای: monomer elution

تعداد نتایج: 26450  

Journal: :Journal of the Japan Society of Powder and Powder Metallurgy 2011

Journal: :Journal of nuclear medicine technology 2003
Chris Tsopelas Peter J Collins Cristina Blefari

OBJECTIVE In the preparation of radiopharmaceuticals, staff receive considerable radiation exposure to the hands during withdrawal of activity from the elution vial, from a combination of the syringe and elution vial activities. In an attempt to reduce the radiation burden to the hands, a simple technique was developed that utilizes a modified lead pot lid and a syringe bearing a long needle wi...

Journal: :Applied and environmental microbiology 1984
D R Dahling B A Wright

Poliovirus-seeded tap water, conditioned with MgCl2 and passed through virus-adsorbing filters, gave better poliovirus recovery than water identically treated but conditioned with AlCl3. Elution of several filter types with beef extract yielded higher recoveries than did elution with glycine. Seeded samples filtered through various filters and stored showed considerable virus loss in 2 days whe...

Journal: :Journal of clinical microbiology 1988
P C Fuchs A L Barry R N Jones

A total of 97 anaerobic bacteria were tested for susceptibility to ampicillin, ampicillin-sulbactam, and amoxicillin-clavulanic acid by broth microdilution and disk elution methods, the results of which were compared with those of the reference agar dilution method. With the broth microdilution method, approximately 95% of MICs were within 1 dilution of those of the reference agar method, with ...

2002
N. Sivaraman R. Kumar S. Subramaniam P. R. Vasudeva Rao

A rapid and high resolution separation of lanthanides by HPLC technique has been developed using Di-(2-ethylhexyl) phosphoric acid (HDEHP) coated reverse phase column and α-hydroxy isobutyric acid as the complexing reagent for elution. A gradient elution technique has been developed for achieving the separation of the entire lanthanide series. Isocratic elution procedure has also been developed...

2011
Y. Song M. Noguchi K. Takatsuki T. Sekiguchi S. Shoji T. Funatsu J. Mizuno M. Tsunoda

This paper reports a gradient elution system for pressure-driven liquid chromatography (LC) on a chip. We have already reported the microfabrication of efficient pillar array columns with low dispersion turns. For faster and more efficient analysis, we fabricated a gradient elution system with a cross-Tesla mixer for the effective mixing of two solutions on a chip with a separation channel of p...

Journal: :Applied and environmental microbiology 1988
G Berg G Sullivan

This study demonstrates that elution of enteroviruses from a mixture of primary- and activated-sludge solids with beef extract at pH 9.2 +/- 0.2 may be less efficient than elution with beef extract at pH 7.2 +/- 0.2 and that elution of enteroviruses from extended-aeration-sludge solids with beef extract is at best no more efficient at pH 9.2 +/- 0.2 than at pH 7.2 +/- 0.2. Thus, the common prac...

Journal: :Analytical biochemistry 2017
Peter Kesa Mangesh Bhide Veronika Lysakova Andrey Musatov

A rapid separation of the ten nuclearly-encoded subunits of mitochondrial cytochrome c oxidase, and ten out of the eleven subunits of cytochrome bc1, was achieved using a short, 50 mm C18-reversed-phase column. The short column decreased the elution time 4-7 fold while maintaining the same resolution quality. Elution was similar to a previously published protocol, i.e., a water/acetonitrile elu...

Journal: :Clinical chemistry 1975
W G Yasmineh N Q Hanson

We have compared two methods for separating the isoenzymes of creatine kinase in serum and measuring their activity: chromatography on diethylaminoethyl-Sephadex A-50, with both continuous and discontinuous gradient elution, and electrophoresis on cellulose acetate. Results by continuous and discontinuous gradient elution correlated well both for tissue extracts and sera. Electrophoresis on cel...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید