نتایج جستجو برای: metal artifact reduction software
تعداد نتایج: 1109039 فیلتر نتایج به سال:
BACKGROUND Metal artifacts appearing as streaks and shadows often compromise readability of computed tomography (CT) images. Particularly in a dental CT in which high resolution imaging is crucial for precise preparation of dental implants or orthodontic devices, reduction of metal artifacts is very important. However, metal artifact reduction algorithms developed for a general medical CT may n...
PURPOSE To investigate dosimetric consequences of patient metal prosthesis in prostate radiotherapy, considering the body heterogeneity, metal artifacts, prostate daily displacements and target delineation. METHODS Three prostate patients with metal prosthesis were simulated with CT images and 3D ultrasound images. Conformal RT treatment plans were generated based on target volumes delineated...
To understand the development of biofilms on metal surfaces, analysis of initial bacterial attachment to surfaces is crucial. Here we present the results of a study, using Shewanella oneidensis MR-1 as a model organism, in which vertical scanning interferometry (VSI) was used to investigate the initial stages of cell attachment to glass, steel and aluminium surfaces. It was found that while VSI...
Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...
PURPOSE To evaluate a method of reducing computed tomography (CT) metal artifacts due to the Fletcher-Suit applicator. METHODS AND MATERIALS We apply a projection-interpolation algorithm to CT images containing artifacts from the brachytherapy applicator. Regions of projection data containing the applicator are interpolated, removing the metal from the projections. A new image is then reconst...
Imaging of the cerebral vessels with use of CT angiogram (CTA) after placement of aneurysmal clips is often limited by clip artifacts. We used a phantom to demonstrate a visible reduction in metal artifact when using the axial technique, compared with the usual CTA helical acquisition. This approach may have some advantage when used for CTA with 64-section scanners in the specific circumstance ...
UNLABELLED The goal of this study was to assess the effect of diaphragmatic respiratory motion on inferior wall cold artifact in myocardial SPECT and to assess the ability of attenuation correction (AC) to correct for this artifact in the presence of diaphragmatic motion. METHODS We used an anthropomorphic phantom with ventricular wall activity, variable ventricular caudal tilt, attenuating l...
PURPOSE To investigate and propose a method of artifact reduction arising from metallic dental materials by applying a slice-encoding for metal artifact correction (SEMAC) technique on T1-weighted spin-echo (SE) imaging at 3 Tesla. MATERIALS AND METHODS The view angle tilting (VAT) technique was adapted to conventional T1-weighted spin-echo (SE) sequence to correct the in-plane distortion, an...