نتایج جستجو برای: intraocular lymphoma
تعداد نتایج: 119669 فیلتر نتایج به سال:
PURPOSE To evaluate changes over time of the anterior capsule opening size after phacoemulsification, based on haptic number and composition of three acrylic intraocular lenses (IOLs). METHODS Fifty-five patients (70 eyes) were included. All underwent phacoemulsification followed by implantation of either an acrylic IOL with two-haptic (one-piece, 26 eyes; three-piece, 22 eyes), or four-hapti...
PURPOSE To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing. METHODS Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Ze...
Study sample Power calculations to determine the sample size were performed (apparently in the preliminary phase of the study). These suggested that a sample of 99 patients in each group was required to detect a 0.4 difference in mean scores between the two groups with 80% power and at a 5% level of significance. All of the patients who underwent bilateral implantation of the multifocal IOL wer...
PURPOSE To demonstrate the methodology described by the American National Standards Institute (ANSI) Standard Subcommittee on Astigmatism Analysis reporting a standardized method of presenting astigmatism data by laser systems that reshape the cornea also applies to toric phakic intraocular lens (IOL) data. METHODS The U.S. Food and Drug Administration trial of the Visian Toric Implantable Co...
We present a new method for subjectively evaluating intraocular lenses (IOLs) without implantation surgery. To illustrate the method, three types of single-piece IOL (equispherical monofocal, rotational symmetric aspheric monofocal, and diffractive bifocal) were assembled into a model eye and evaluated using an ocular adaptive optics system by a single subject. To separate the spherical aberrat...
PURPOSE To show the clinical use of the NIDEK OPD-Scan wavefront aberrometer and OPD-Station software in anterior segment surgery and pathology. METHODS Case examples are presented along with discussion about the relevant clinical data obtained from the OPD-Scan and OPD-Station software. RESULTS Six case examples including cataract surgery, secondary IOL implantation, phakic intraocular len...
I f it were possible to adjust the refraction of a pseudophakic eye by means of an adjustable posterior chamber intraocular lens (PC/IOL), subjective comfort or visual function would be improved. This is especially true in children. Several approaches to create an adjustable intraocular lens (IOL) are currently under study. This field is still in an early stage of its evolution. The *Acri.Tec A...
PURPOSE The aim of this study was to design and evaluate in the laboratory a new intraocular lens (IOL) intended to provide superior ocular optical quality by reducing spherical aberration. METHODS Corneal topography measurements were performed on 71 cataract patients using an Orbscan I. The measured corneal surface shapes were used to determine the wavefront aberration of each cornea. A mode...
We hypothesize that an intraocular lens (IOL) with higher-order aspheric surfaces customized for an individual eye provides improved retinal image quality, despite the misalignments that accompany cataract surgery. To test this hypothesis, ray-tracing eye models were used to investigate 10 designs of mono-focal single lens IOLs with rotationally symmetric spherical, aspheric, and customized sur...
PURPOSE To report an exchange technique for opacified hydrophilic acrylic intraocular lenses (IOLs). METHODS . Twenty patients with two different types of opacified hydrophilic acrylic IOLs underwent IOL exchange by a single surgeon. Circumferential enlargement of the pre-existing capsulorrhexis was a critical step of the procedure, and resulted in expression of the IOL with minimal traction ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید