نتایج جستجو برای: insertion torque
تعداد نتایج: 83716 فیلتر نتایج به سال:
BACKGROUND Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of OMIs may provide a more accurate and immediate diagnosis of implant-root contact (target condition...
Background: The primary stability is a determinant clinical condition for the success of different dental implants macro-design in bone density using validated and repeatable vitro technique employing solid rigid polyurethane blocks. Materials Methods: Five 3.8 × 13 mm2 each (i.e., IK—tapered; IC—cylindric; IA—active blade shape) were positioned into 20- 30- pounds per cubic foot (PCF) Bucco-li...
OBJECTIVE The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. METHODS Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We co...
OBJECTIVES This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. MATERIALS AND METHODS This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirty-two mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits ...
STUDY DESIGN Multicenter intraoperative biomechanical analysis. PURPOSE This study aimed to assess the maximal insertional torque (MIT) of lateral mass screw (LMS) and pedicle screw (PS) in the cervical or thoracic vertebrae during surgery. METHODS During posterior spinal fusion, cervical or thoracic multi-axial screws were placed at different cervical or thoracic levels and the MIT was rec...
The aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1 (30o X 0.6 mm) and G2 (45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insert...
PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end pla...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید