The Fast Spoiled Gradient Echo (FSPGR) sequence is often used in MRI to create T1-weighted images. The signal intensity generated by this sequence depends on the applied flip angle. Knowing the correct flip angle is essential for the determination of T1-maps by means of an FSPGR based Variable Flip Angle (VFA) approach. Also, quantitatively determining the concentration of contrast agent in cas...
Fluorescence microscopy has become a widely used tool for studying various biological structures of in vivo tissue or cells. However, quantitative analysis of these biological structures remains a challenge due to their complexity which is exacerbated by distortions caused by lens aberrations and light scattering. Moreover, manual quantification of such image volumes is an intractable and error...
Portable NMR systems generally suffer from poor field homogeneity and are therefore used more commonly for imaging and relaxation measurements rather than for spectroscopy. In recent years, various approaches have been proposed to increase the sample volume that is usable for spectroscopy. These include approaches based on manual shimming and those based on clever combinations of modulated radi...
abstract background: adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-y fields for the treatment of hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. in each of these situations, there is a po...
aims: the aim of the present work is (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 mv small photon fields in a medium encompassing heterogeneity and (2) compare these results with measured results obtained using gafchromic film ebt2. materials and methods: authors employed kailwood (pinus wallichiana) to mimic lung. briefly, seven kailwood plates, each measuri...
Introduction: Cardiac imaging, for both real-time and triggered imaging, requires a high data acquisition rate. Spiral trajectories achieve this rate; however, their advantages are shadowed by off-resonance blurring and distortion effects. Current techniques to correct for this image degradation do not easily or quickly account for the different effects specifically field inhomogeneities and co...
Abstract: Segmentation of magnetic resonance (MR) images plays an important role in quantitative analysis of brain tissue morphology and pathology. However, the inherent effect of image-intensity inhomogeneity renders a challenging problem and must be considered in any segmentation method. For example, the adaptive fuzzy c-mean (AFCM) image segmentation algorithm proposed by Pham and Prince can...
The well-known variability in the distribution of high frequency electromagnetic fields in the human body causes problems in the analysis of structural information in high field magnetic resonance images. We describe a method of compensating for the purely intensity-based effects. In our simple and rapid correction algorithm, we first use statistical means to determine the background image nois...
Modern treatment planning systems provide accurate dosimetry in heterogeneous media (such as a patient' body) with the help of tissue characterization based on computed tomography (CT) number. However, CT number depends on the type of scanner, tube voltage, field of view (FOV), reconstruction algorithm including artifact reduction and processing filters. The impact of these parameters on CT to ...