نتایج جستجو برای: in vivo dosimetry radiotherapy dose prediction

تعداد نتایج: 17079382  

Journal: :Clinical oncology (Royal College of Radiologists (Great Britain)) 2016
M D Mason R Moore G Jones G Lewis J L Donovan D E Neal F C Hamdy J A Lane J N Staffurth

AIMS The treatment of prostate cancer has evolved markedly over the last 40 years, including radiotherapy, notably with escalated dose and targeting. However, the optimal treatment for localised disease has not been established in comparative randomised trials. The aim of this article is to describe the history of prostate radiotherapy trials, including their quality assurance processes, and to...

Journal: :iranian journal of radiation research 0
t. cakir department of radiation oncology, medical faculty, yuzuncu yil university 65080, van, turkey a. gur department of physicalchemistry, science and art faculty, yuzuncu yil university, 65080, van, turkey a. arasoglu department of nuclear physics, science and art faculty, yuzuncu yil university, 65080, van, turkey

background: advances in radiation dosimetry concepts and the development of primary measurement standards based on absorbed dose to water over the last decades offer the possibility to calibrate ionisation chambers directly in terms of absorbed dose to water. the aim of this study is the investigation on utility of artificial body fluid (abf) instead of water by comparing dosimetric measurement...

Journal: :Medical physics 2011
James A Tanyi Kevin D Nitzling Camille J Lodwick Alan L Huston Brian L Justus

PURPOSE Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. METHODS The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and...

C Knaup, F Akbari F Khorshidi, M Ghorbani, M T Bahreyni Toosi N Mohammadian

Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3...

2012
Antony Palmer David Bradley Andrew Nisbet

This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed...

Ahad Zainali, Leila Mahani

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...

2009
Rajesh Kumar S.D. Sharma Sudesh Despande Yogesh Ghadi V.S. Shaiju H.I. Amols Y. S. Mayya

A novel IMRT phantom was designed and fabricated using Acrylonitrile Butadiene Styrene (ABS) plastic. Physical properties of ABS plastic related to radiation interaction and dosimetry were compared with commonly available phantom materials for dose measurements in radiotherapy. The ABS IMRT phantom has provisions to hold various types of detectors such as ion chambers, radiographic/radiochromic...

Journal: :Physics in medicine and biology 2011
I Mrčela T Bokulić J Izewska M Budanec A Fröbe Z Kusić

A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...

Journal: :journal of biomedical physics and engineering 0
m. dehghan master student of physics, department of physics, yazd university, yazd, iran h. mokhtari assistant professor of physics, department of physics, yazd university, yazd, iran f. bouzarjomehri associate professor of medical physics, shahid sadoughi university of medical sciences, yazd, iran

background: over recent decades, modern protocols of external beam radio¬therapy and radiation techniques such as intensity-modulated radiotherapy (imrt) have been developed. these methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3d dosimetry system that has high sensitivity and is capable of measuring and verifying the complex ...

2017
Angelia Tran Kaley Woods Dan Nguyen Victoria Y. Yu Tianye Niu Minsong Cao Percy Lee Ke Sheng

BACKGROUND It is useful to predict planned dosimetry and determine the eligibility of a liver cancer patient for SBRT treatment using knowledge based planning (KBP). We compare the predictive accuracy using the overlap volume histogram (OVH) and statistical voxel dose learning (SVDL) KBP prediction models for coplanar VMAT to non-coplanar 4π radiotherapy plans. METHODS In this study, 21 liver...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید