Journal: :journal of artificial intelligence in electrical engineering 2016
parisa alipour mehdi salimi

although lcl filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. recently, the single-loop control strategy has beensuggested for l or lc filter based grid-connected inverters. however, the use of single-loopcontrol directly in lcl filter-...

Journal: :International journal of recent technology and engineering 2023

The microgrid has been defined to cope with the large penetration of distributed generations (DGs). is capable operating in grid-connected mode (GC) and islanded (IS). In microgrid, (DGs) are always connected power network via inverters. Grid Connected mode, DGs commonly acts as current controlled sources retain a high grid-current quality fast dynamic response photovoltaic wind generation syst...

2011
Jong-Yul Kim June Ho Park Heung-Jae Lee

As usual, the microgrid operates in grid-connect mode, but, when a fault occurs in the upstream grid, it should disconnect and shift into islanded operation mode. In grid-connect mode, the controlling power at the PCC is necessary management function rather than the frequency and voltage. However, the controlling the frequency and voltage is asked in islanded mode. To achieve these management g...

2017
Niraj Kumar Choudhary Soumya Ranjan Mohanty Ravindra Kumar Singh

Received Sep 4, 2017 Revised Oct 21, 2017 Accepted Nov 18, 2017 This paper presents an investigation about the impact of integrating renewable energy based generation sources on the existing distribution system in terms of load sharing. The study of load sharing among various distributed generators (DGs) and utility grid has been performed for two cases: (a) when equivalent source based DG is c...

2013
T.Maheswaran M.Venkateswaran

Recently a new and simple method to mitigate the transient instability of squirrel cage induction generators (IG) without using any additional equipment. The majority of the fixed speed wind turbines are equipped with squirrel cage IG and ac connected to the power system. During a fault in power system, voltage and rotor speed instability may occur, especially when the strength of the system co...

2012
A. Chaouachi R. M. Kamel K. Nagasaka

This paper presents a novel methodology for Maximum Power Point Tracking (MPPT) of a grid-connected 20 kW Photovoltaic (PV) system using neuro-fuzzy network. The proposed method predicts the reference PV voltage guarantying optimal power transfer between the PV generator and the main utility grid. The neuro-fuzzy network is composed of a fuzzy rule-based classifier and three Radial Basis Functi...

2017
Dong-Jun Won

Abstract—This paper presents hierarchical operation strategies which are minimizing operation error between day ahead operation plan and real time operation. Operating power systems between centralized and decentralized approaches can be represented as hierarchical control scheme, featured as primary control, secondary control and tertiary control. Primary control is known as local control, fea...