نتایج جستجو برای: goldmann applanation tonometer

تعداد نتایج: 2316  

Journal: :The British journal of ophthalmology 2005
P-A Tonnu T Ho K Sharma E White C Bunce D Garway-Heath

AIM To compare the inter-method agreement in intraocular pressure (IOP) measurements made with four different tonometric methods. METHODS IOP was measured with the Goldmann applanation tonometer (GAT), Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact tonometer (NCT) in a randomised order in one eye of each of 105 patients with ocular hypertension or glaucoma. Three ...

2011
Turki M AlMubrad

BACKGROUND The purpose of this study was to assess the repeatability and reproducibility of the PT100 noncontact tonometer and to compare its consistency with the Goldmann applanation tonometer (GAT) in measuring intraocular pressure (IOP). METHODS Triplicate IOP measurements were obtained on two separate occasions using the PT100 and GAT from randomly selected eyes in 66 healthy volunteers a...

Journal: :Ciência Animal Brasileira 2022

Abstract This study aimed to compare values of intraocular pressure (IOP) by different tonometers and evaluators (veterinary ophthalmologist specialist veterinary not a specialist). For this, 30 rabbits were used, in all (n = 60 eyes), the IOP was initially measured with rebound tonometer (model TD - 8000 portable, Apramed Indústria e Comércio de Equipamentos Médicos Ltda) and, subsequently, an...

2017
Behrooz Kouchaki Hassan Hashemi Abbasali Yekta Mehdi khabazkhoob

PURPOSE To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. METHODS In this cross-sectional study, volunteers with normal ophthalmic examination and n...

2014
Matthias Neuburger Juliane Großwendt Sonja Lautebach Philip Maier Florian Birnbaum Daniel Böhringer Jens Funk Jens Friedrich Jordan Thomas Reinhard

Unspecified Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: http://doi.org/10.5167/uzh-101903 Published Version Originally published at: Neuburger, M; Grosswendt, J; Lautebach, S; Maier, P; Birnbaum, F; Böhringer, D; Funk, J; Jordan, J F; Reinhard, T (2014). Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral...