نتایج جستجو برای: gas meter

تعداد نتایج: 270407  

2013
Qihui Wang Lijun Xie Bo Zhu Yao Zheng Shihua Cao

In this paper, a novel cataluminescence (CTL)-based sensor array consisting of nine types of catalytic materials is developed for the recognition of several harmful gases, namely carbon monoxide, acetone, chloroform and toluene. First, the experimental setup is constructed by using sensing nanomaterials, a heating plate, a pneumatic pump, a gas flow meter, a digital temperature device, a camera...

2006
M. Moghavvemi S. K. Wong

Automatic Meter Reading (AMR) is the remote collection of consumption data from customer’s utility meters over telecommunications, radio, power line and other links. AMR provides water, electric and gas utility−service companies the opportunities to streamline metering, billing and collection activities, increase operational efficiency and improve customer service. Utility company uses technolo...

Journal: :Clinical chemistry 1973
O A Mamer B F Gibbs

All the metabolically important C1 through C5 fatty acids and lactic, pyruvic and fl-hydroxybutyric acids can be gas chromatographed surprisingly well on the common 2-meter 3% methylphenylsilicone (e.g., “OV-17”) column when a late-eluting silylating reagent such as trimethylsilylimidazole is used. In these circumstances, the trimethylsilyl esters elute in an interval that is free of the reagen...

Journal: :Optics express 2014
B Debord M Alharbi L Vincetti A Husakou C Fourcade-Dutin C Hoenninger E Mottay F Gérôme F Benabid

We report on damage-free fiber-guidance of milli-Joule energy-level and 600-femtosecond laser pulses into hypocycloid core-contour Kagome hollow-core photonic crystal fibers. Up to 10 meter-long fibers were used to successfully deliver Yb-laser pulses in robustly single-mode fashion. Different pulse propagation regimes were demonstrated by simply changing the fiber dispersion and gas. Self-comp...

2005
Kunal K. Das Yuri V. Rostovtsev Kevin Lehmann Marlan O. Scully

We develop a simple thermodynamic model to describe the heat transfer mechanisms and generation of acoustic waves in photoacoustic Raman spectroscopy by small particulate suspensions in a gas. Using Langevin methods to describe the thermal noise we study the signal and noise properties, and from the noise equivalent power we determine the minimum number density of the suspended particles that c...

Journal: :Science 2005
F S Chapin M Sturm M C Serreze J P McFadden J R Key A H Lloyd A D McGuire T S Rupp A H Lynch J P Schimel J Beringer W L Chapman H E Epstein E S Euskirchen L D Hinzman G Jia C-L Ping K D Tape C D C Thompson D A Walker J M Welker

A major challenge in predicting Earth's future climate state is to understand feedbacks that alter greenhouse-gas forcing. Here we synthesize field data from arctic Alaska, showing that terrestrial changes in summer albedo contribute substantially to recent high-latitude warming trends. Pronounced terrestrial summer warming in arctic Alaska correlates with a lengthening of the snow-free season ...

2004
Aaron Johnson Tom Kegel

This paper analyzes the uncertainty of a secondary flow measurement facility that calibrates a significant fraction of United States and foreign flow meters used for custody transfer of natural gas. The facility, owned by the Colorado Experimental Engineering Station Incorporated (CEESI), is located in Iowa. This facility measures flow with nine turbine meter standards, each of which is traceab...

Journal: :Analytical chemistry 2010
Chaudhery Mustansar Hussain Chutarat Saridara Somenath Mitra

The synthesis of the gas chromatography stationary phase by molecular self-assembly of carbon nanotubes (CNTs) via a novel ethanol chemical vapor deposition process is presented. A major advantage is that ethanol was found to be an excellent carbon source that generated highly pure multiwalled carbon nanotubes with very little nontubular carbon impurities. The nanotubes were not vertically alig...

Journal: :British journal of anaesthesia 1975
F Meade J B Owen-Thomas

A paramagnetic method of carbon dioxide analysis enables the simultaneous analysis of carbon dioxide and oxygen to be made at 2-min intervals. The method depends upon observing the change of oxygen concentration in a gas mixture before and after absorbing the carbon dioxide component. The carrier-gas in the experiments reported was nitrogen. The output of the paramagnetic meter was measured bot...

2015
Michael David Tay Ching En Marcus Maslina Yaacob Mohd Rashidi Salim Nabihah Hussin Mohd Haniff Ibrahim Sevia Mahdaliza Idrus Nor Hafizah Ngajikin Asrul Izam Azmi

Laboratory design of an ozone concentration regulator which is build on the theory of continuity equation for gas flow in parallel pipes in conjunction with the ozone elimination potentials of an ozone destructor is presented. At an initial oxygen flow rate of 33.33 cms, ozone concentration was generated and varied between 429.30 parts per million (ppm) to 3826.60 ppm. Similarly at an initial o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید