نتایج جستجو برای: fricke gel dosimeter

تعداد نتایج: 107206  

Ahmad Mostaar, Mohammad Houshyari Zeinab Sattari

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

Journal: :Dyes and Pigments 2021

Abstract Fricke gel dosimeters were prepared using a matrix based on poly(vinyl-alcohol) chemical cross-linked with glutaraldehyde and loaded Xylenol Orange. The samples irradiated gamma rays to doses in the range of 5–30 Gy consequent color changes investigated by spectrophotometric colorimetric techniques. Starting from measurement transmittance spectra, an analysis was carried out considerin...

Journal: :E-polymers 2021

Abstract Cancer prevention and treatment are currently the focus of most research. Dose verification is an important step for reducing improper dose deposition during radiotherapy. To mend traditional gel dosimeters 3D verification, a novel rare-earth nanoparticle-based composite was prepared, which has good radioluminescence property reusability. It promising phantom material new dosimeter. TE...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran ghorban safaeian m.sc., in medical physics, mashhad university of medical sciences, mashhad, iran mohammad hosein bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahram baiani m.sc., in medical engineering, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

2005

1Wright, S., Genetics, 16, 97-159 (1931). 2 Wright, S., Jour. Genetics, 30, 243-256 (1934). 3Fisher, R. A., Proc. Roy. Soc. Edinburgh, 42, 321-341 (1922). 4Wright, S., Amer. Nat., 63, 556-561 (1929). 5 Fisher, R. A., The Genetical Theory of Natural Selection, Oxford, Clarendon Press, 272 pp. (1930). 6 Fisher, R. A., Proc. Roy. Soc. Edinburgh, 50, 205-220 (1930). 7 Haldane, J. B. S., The Causes ...

2017
Shih-Ming Hsu Chao-Hsiung Hung Yi-Jen Liao Hsiao-Mei Fu Jo-Ting Tsai Yung-Hui Huang David Y. C. Huang

CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotolumines...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید