نتایج جستجو برای: electrode response decay

تعداد نتایج: 1103418  

2007
Joaquín A. Ortuño Vicente Ródenas Mª Soledad García Mª Isabel Albero Concepción Sánchez-Pedreño

The construction and electrochemical response characteristics of a poly(vinyl chloride) (PVC) membrane selective electrode for the determination of tiapride (TPD) are described. The sensing membrane comprised an ion-pair formed between the protonated drug and tetraphenylborate (TPB) in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The ele...

ژورنال: مواد پرانرژی 2017

Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...

Journal: Nanochemistry Research 2016

In the present study, a new chemically modified carbon paste electrode (CPE) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of Mo (VI) using differential pulse voltammetry. The electrode was prepared using magnetic nickel zinc ferrite nanocomposite (Ni0.5Zn0.5Fe2O4), as the modifier in CPE (Ni0.5Zn0.5Fe2O4/CPE). Mo (VI) was determined after preconcentr...

In this paper studies of overvoltage and capacitance measurements at silver cathodes in aqueous perchloric acid at room temperature are described. Capacitances were deduced from open-circuit potential decay measurements. The increase of overvoltage and the growth of the measured capacitances in the course of electrolysis are attributed to a growing pseudocapacitance component. This is anal...

2017
Christofer W. Bester Luke Campbell Adrian Dragovic Aaron Collins Stephen J. O'Leary

Objective: Lay the groundwork for using electrocochleography (ECochG) as a measure of cochlear health, by characterizing typical patterns of the ECochG response observed across the electrode array in cochlear implant recipients with residual hearing. Methods: ECochG was measured immediately after electrode insertion in 45 cochlear implant recipients with residual hearing. The Cochlear Response ...

A new Schiff base 2-aminothiophenol furfural self assembled monolayer (SAM) has been fabricated on a bare gold electrode as a novel sensor for determination of dopamine. Electrochemical impedance spectroscopywas utilized to investigate the properties of the Au 2-aminothiophenol furfural self assembled monolayermodified electrode (Au ATF SAM-ME) using the [Fe(CN)6]3-/4- redox couple. The electro...

Hamideh Ghanei Jafar Hosseinalizadeh Khorasani Mohammad Kazem Amini, Shahram Tangestaninejad

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

Journal: :analytical and bioanalytical chemistry research 2014
a. shokrollahi a. abbaspourb a. naghashian haghighia a. h. kianfar

a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m  with nernstian slope of 19.64 ± 0.15 mv decade-1...

2008
Jietae Lee Su Whan Sung Seungjae Lee Dae Ryook Yang

Introduction The concentration of ion H (pH) in solution plays very important role in chemical, biological and physical processes. Since Cremer (1906) first reported the pH response of oxide glasses, many theoretical researches about the glass electrode and its applications have been carried out. The glass electrode is stable mechanically and chemically and can be used in the wide range of solv...

2013
Shigehiro Takahashi Naoyuki Abiko Jun-ichi Anzai

The surface of a glassy carbon (GC) electrode was modified with reduced graphene oxide (rGO) to evaluate the electrochemical response of the modified GC electrodes to hydrogen peroxide (H₂O₂) and hydrazine. The electrode potential of the GC electrode was repeatedly scanned from -1.5 to 0.6 V in an aqueous dispersion of graphene oxide (GO) to deposit rGO on the surface of the GC electrode. The s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید