نتایج جستجو برای: dynamic hip screw dhs
تعداد نتایج: 482660 فیلتر نتایج به سال:
The reduction of hip fractures prior to using dynamic hip screw devices can be challenging. The use of folded paper recreates an optimal angle of 135 degrees to assess adequacy of hip fracture reduction and to alert the surgeon as to the precise entry point of the guidewire in the lateral cortex of the femur.
OBJECTIVE To determine the effect of reinforced calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal in a cadaveric model. METHODS The lag screws of dynamic hip screw implants were inserted and subsequently removed in 8 matched pairs of cadaveric, osteoporotic femurs to create a femoral neck defect. One of each pair had the defect augmented ...
BACKGROUND AND PURPOSE Virtual reality (VR) simulation offers a safe, controlled, and effective environment to complement training but requires extensive validation before it can be implemented within the curriculum. The main objective was to assess whether VR dynamic hip screw (DHS) simulation has a training effect to improve objective performance metrics. PATIENTS AND METHODS 52 surgical tr...
OBJECTIVE To compare outcomes in octogenarians with younger patients up to 1 year after undergoing dynamic hip screw fixation for intertrochanteric fractures to see the effectiveness of the implant. METHODS The retrospective case-control study was conducted at The Aga Khan University and comprised records of patients who underwent dynamic hip screw surgery between January 1, 2010, and Decembe...
Although the importance of lateral femoral wall integrity is increasingly being recognised in the treatment of intertrochanteric fracture, little attention has been put on the development of a secondary post-operative fracture of the lateral wall. Patients with post-operative fractures of the lateral wall were reported to have high rates of re-operation and complication. To date, no predictors ...
The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the shaft or the neck of the femur, or a combination of both. In a prospective series of 108 consecutive displaced intertrochanteric fractures we used combined dynamic compression. The patients were followed clinically and radiologically...
The mechanical complications of osteosyntheses after hip fractures are previously investigated by mostly static or dynamic uniaxial loading test systems. However, the physiologic loading of the hip joint during a normal gait is a multiplanar, dynamic movement. Therefore, we constructed a system to test osteosyntheses for hip fractures under physiologic multiplanar loading representative of norm...
Fractures of the proximal femur are a big challenge in traumatology. Rapid strides in implant and instrumentations in quest of ideal fixation of pertrochanteric and subtrochanteric femoral fractures have made various options available like Fixed-angled nail plate, Screw plates, Angled blade plate, Dynamic Hip Screw etc. The present study aims to study the role of standard PFN as a minimal invas...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید