Introduction: Irregular/blocked fields are routinely used in radiotherapy. The doses of these fields are usually calculated by means of equivalent square method that is inherently prone to uncertainty. On the other hand, Clarkson’s sector integration method is a dose calculation method which offers far better accuracy in dose calculation of irregular fields. The Scatter Air Ratio (SAR) of an in...
We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3 x 3 cm2 to 25 x 25 cm2) and depths (d(max) to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric r...
During implementation of the total skin electron treatment, using six-dual-field technique, at radiotherapy department a large number of measurements are needed. To assess depth dose curve required by clinicians and dose uniformity over a whole treatment plane, combinations of different irradiation parameters are used (electron energy, beam angle, scatterers). Measurements for each combination ...
The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...
PURPOSE The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of...
PURPOSE To evaluate dosimetric variations of planning target volume (PTV) on critical organs such as rectal wall, bladder and femoral head, when the patient size changes due to weight loss in prostate volumetric modulated arc therapy (VMAT). METHODS Three patients with small (32.0 cm3 ), medium (48.4 cm3 ) and large (86.5 cm3 ) prostate, selected from a group of 30 were planned for prostate V...
In this study, we evaluate the attenuation of the dose due to barium-impregnation in the region between the surface of an electronic brachytherapy (EBT) balloon applicator for accelerated partial breast irradiation (APBI) and the prescription point at 1 cm depth in tissue. To perform the study, depth dose curves were calculated using a general purpose multi-particle transport code (FLUKA) for a...
Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...
Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...
Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...