نتایج جستجو برای: collimator angle

تعداد نتایج: 133117  

2005
Ryan Acosta Matthias Ehrgott Allen Holder Daniel Nevin Josh Reese Bill Salter

The design of a radiotherapy treatment includes the selection of beam angles (geometry problem), the computation of a fluence pattern for each selected beam angle (intensity problem), and finding a sequence of configurations of a multilef collimator to deliver the treatment (realization problem). While many mathematical optimization models and algorithms have been proposed for the intensity pro...

Journal: :Computers & OR 2013
Z. Caner Taskin Mucahit Cevik

We consider the problem of decomposing Intensity Modulated Radiation Therapy (IMRT) fluence maps using rectangular apertures. A fluence map can be represented as an integer matrix, which denotes the intensity profile to be delivered to a patient through a given beam angle. We consider IMRT treatment machinery that can form rectangular apertures using conventional jaws, and hence, do not need so...

Alireza Emami-Ardekani Alireza Mardanshahi, Faraz Kalantari, Mahmoud Bagheri Mohammad Sobhan Ardekani Nasim Namiranian Reza Nafisi-Moghadam Seid Kazem Razavi-Ratki, Seyed Hossein Razavi,

Introduction:In an ideal parallel-hole collimator, thickness of septal material should be sufficient to stop more than 95% of incident photons. However, some photons pass the septa without interaction or experience scattering before they reach the detector. In this study, we determined different contribution of collimator responses consist of geometrical response, septal penetr...

2008
Gengsheng Lawrence Zeng

In single photon emission computed tomography (SPECT), pinhole and cone-beam collimators are used for small object imaging. It is accepted that a pinhole collimator should be used if the object is very small, and the cone-beam collimator should be used if the object is larger. This paper presents criteria to determine which collimation geometry is more advantageous in terms of spatial resolutio...

2006
Igor Zagorodnov

Using a recently developed time domain numerical approach we calculate the short-range geometric wakefields of 3D collimators and compare with analytical models. We find, in the diffractive regime, that the transverse mode kick factor can be approximated from the change in field energy between the beam pipe and the collimator if the collimator is long, or using a “field clipping” estimate if it...

Jalil Pirayesh Islamian, Parvaneh Darkhor Samira Abbaspour

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

2013
Mohammad Reza Abdi M. R. Abdi K. H. Rezaee P. Shayan A. Farzaneh

This paper is aimed to investigate the design of an optimized neutron radiography system that utilizes the flux of a reactor. Moderation, collimation aspects are studied. A Monte Carlo code, MCNP4C, was utilized to achieve a maximum and more homogenous neutron flux in the collimator outlet next to the image plane, taking into account geometric characteristics. It was possible to obtain a normal...

Journal: :Medical physics 2005
Joel Y C Cheung K N Yu

We have calculated the dose enhancements close to metal implants in Gamma Knife radiosurgery using different beam sizes, i.e., 4, 8 and 18 mm collimator helmets sin addition to the previous calculations using the 14 mm collimator helmetd. For the 8 and 18 mm helmets, the obtained results were similar to those obtained using the 14 mm helmet, which can be explained by the similar beam profiles w...

2014
Zhen Chen Carlaton Wong Sean Lubner Shannon Yee John Miller Wanyoung Jang Corey Hardin Anthony Fong Javier E. Garay Chris Dames

A thermal diode is a two-terminal nonlinear device that rectifies energy carriers (for example, photons, phonons and electrons) in the thermal domain, the heat transfer analogue to the familiar electrical diode. Effective thermal rectifiers could have an impact on diverse applications ranging from heat engines to refrigeration, thermal regulation of buildings and thermal logic. However, experim...

2014
Robert J. Wilson

The single-hole collimator limits the field of view of a scintillation probe to a single organ. The sensitivity for counting is approximately equal over the entire field of view. The most common use of this collimator is for iodine uptake measurements of the thyroid. An example of this "flat-field collimator" is shown (Fig. I). The sensitivity profile at the working distance illustrates the rel...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید