نتایج جستجو برای: catheter ablation atrial function

تعداد نتایج: 1356655  

Journal: :Journal of the American College of Cardiology 2015

Journal: :The Cochrane library 2022

Objectives This is a protocol for Cochrane Review (intervention). The objectives are as follows: To determine the efficacy and safety of any catheter ablation in people with first diagnosed, paroxysmal, persistent, long‐standing persistent atrial fibrillation versus medical therapy.

2012
Anand N Ganesan Suchi Grover Rajiv Mahajan Sachin Nayyar Dan Sunnarborg Tom Lloyd Prashanthan Sanders Joseph Selvanayagam

Background To date, preclinical studies evaluating MRI-guided ablation have used non-irrigated catheters limited to test lesions in the right heart. Modern complex EP procedures require externally irrigated catheters to produce adequate lesion depth. We present the first feasibility study of an externally-irrigated MRI-compatible ablation catheter, and integrated EP pacing and recording system....

Journal: :Journal of Thoracic Disease 2023

Background: The clinical effectiveness and efficiency of a steerable sheath for radiofrequency catheter ablation (RFCA) in Chinese patients with atrial fibrillation (AF) needs to be compared fixed curve optimize RFCA procedure.

Journal: :Journal of atrial fibrillation 2017
Andres Enriquez Jackson J Liang Pasquale Santangeli Francis E Marchlinski Michael P Riley

We report the case of a 66 year-old male who underwent catheter ablation for drug-refractory paroxysmal atrial fibrillation (AF) at our institution. Radiofrequency catheter ablation was performed using a three-dimensional electroanatomical mapping system. During ablation of the pulmonary veins (PV), right atrial ectopics were noted to repeatedly trigger AF and atrial tachycardia (AT). After PV ...

2012
Jason G Andrade Marc Dubuc Peter G Guerra Laurent Macle Lena Rivard Denis Roy Mario Talajic Bernard Thibault Paul Khairy

Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillatio...

Journal: :Journal of cardiovascular electrophysiology 1994
H Calkins C Mann S Kalbfleisch J J Langberg F Morady

INTRODUCTION Recent studies have demonstrated that the most common site of accessory pathway conduction block following the introduction of a premature atrial stimulus during atrial pacing is between the accessory pathway potential and the ventricular electrogram, consistent with block at the ventricular insertion of the accessory pathway. However, no prior study has evaluated the site of condu...

Journal: :Journal of atrial fibrillation 2008
John V Wylie Mark E Josephson

BACKGROUND Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. METHODS AND RESULTS Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were groupe...

2008
Yong-Mei Cha Thomas M. Munger Robert F. Rea Peter A. Brady Arshad Jahangir Kristi H. Monahan Bernard J. Gersh Stephen C. Hammill

Background—Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. Methods and Results—Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were grouped ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید