نتایج جستجو برای: amperometric sensor

تعداد نتایج: 190679  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده شیمی 1390

abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم پایه 1392

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Journal: :The American journal of physiology 1999
Kerstin Rebrin Garry M Steil William P van Antwerp John J Mastrototaro

The present study investigated the relationship between blood and subcutaneous interstitial fluid (ISF) glucose by employing an amperometric glucose sensor specifically developed for 3-day continuous glucose monitoring. The apparent sensor sensitivity and ISF glucose equilibration delay were estimated on separate days during hyperglycemic clamps in four dogs in which insulin was either suppress...

Journal: :Clinical chemistry 1994
P Arquint M Koudelka-Hep B H van der Schoot P van der Wal N F de Rooij

For an example of a silicon-based micromachined analyzer, we describe a combined PO2, PCO2, and pH sensor designed for extracorporeal blood gas monitoring. The clinically well-accepted amperometric (PO2) and potentiometric (PCO2, pH) sensing principles are used, realized in a planar and miniaturized form on a single silicon chip (6 x 22 mm). The transducer part of the chip is fabricated by stan...

2012
C.S. Pundir Jagriti Narang Nidhi Chauhan Preety Sharma Renu Sharma

BACKGROUND & OBJECTIVES The use of epoxy resin membrane as a support for immobilization of enzyme has resulted into improved sensitivity and stability of biosensors for uric acid, ascorbic acid and polyphenols. The present work was aimed to prepare an improved amperometric biosensor for determination of serum cholesterol required in the diagnostics and management of certain pathological conditi...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2003
sayed mahdi golabi mirzazadeh jalil

a thin film of epinephrine (ep) was electrochemically deposited on the surface of glassy carbon electrode previously activated in nahco3 solution. the cyclic voltammograms of the modified electrode indicate that the surface confined ep are strongly dependent on the solution ph, as expected for quinone/hydroquinone functionalities. the ep-modified glassy carbon electrode exhibited catalytic acti...

Journal: :Journal of Electrochemical Science and Engineering 2021

Various carbon-based sensors (graphene, carbon nanotubes, graphite, pencil glassy carbon, etc.) have distinctive behavior and a broad range of importance for identifying sex hormones like estriol, estradiol, estrone, progesterone, testosterone. The current review emphasizes voltammetric, amperometric, electrochemical impedance spectroscopic methods detecting some these hormones. existence, stru...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید